Settings to be made for this type of installation
Parameters
Access
Settings to be made See chapter
INSTALLATION
Installer level
#SYSTEM
menu
EXTENDED
"Displaying the parameters in extended mode", page 102
I.SYST
(1)
Installer level
#SYSTEM
menu
BUFFER TANK
"Setting the parameters specific to the installation", page
P.DHW
(1)
Installer level
#SYSTEM
menu
PUMP
BOILER PUMP
Installer level
#SYSTEM
menu
ALL
(1) The parameter is only displayed if
INSTALLATION
parameter is set to
EXTENDED
The DHW part is maintained at the DHW set point by the
boiler.
The heating zone is maintained at the set temperature
calculated according to the outside temperature. The zone
is reheated when the heating buffer temperature sensor
O
falls -6°C below the calculated set temperature.
Reheating in the heating zone stops when the heating
buffer temperature rises above the calculated set
temperature.
AFC 18 - AFC 24 - AFC 30
5. Installation
09/07/2015 - 300026439-07
75