5.8
Electrical connections
5.8.1.
Control unit
The boiler is fully pre-wired. The electricity supply is made via
connection cable to the mains (hard mounted). All other external
connections can be made to the connection connectors (low
voltage).
Power the appliance via a circuit which includes a remote omnipolar
switch with a gap of more than 3 mm.
Single phase power supply: 230 V (+6% / -10%) - 50 Hz. Power
supply cable premounted.
Connect the boiler to a 6-amp circuit breaker - Type C.
CAUTION
Keep to the polarity shown on the terminals: phase (L),
neutral (N) and earth
*
.
A
Routing of the 230 V cables
Z
Routing of the sensor cables
CAUTION
Disconnect the power supply at the mains before carrying
out any work on the appliance or accessories connected
to the appliance.
C
0
0
3
8
4
9
-B
1
2
PC
U
SC
U
AFC 18 - AFC 24 - AFC 30
5. Installation
09/07/2015 - 300026439-07
59