For example
A
STOP DRYING TEMP
:
47 °C
Z
START DRYING TEMP
:
20 °C
R
NB DAYS DRYING
T
Normal regulation (End of drying)
Y
Heating temperature setting (°C)
Every day at midnight (00:00): the set point (
START
DRYING TEMP
) is recalculated and the remaining number
of days (
NB DAYS DRYING
) is decremented.
n
ROOM S.INFL
Used to adjust the influence of the room sensor on the water
temperature for the circuit concerned.
Adjustment Description
0
No influence (remote control fitted in a location with no
influence)
1
Slight influence
3
Average influence (recommended)
10
Room thermostat type operation
n
NIGHT
This parameter is displayed if at least one circuit does not
include a room sensor.
For circuits without a room sensor:
4
NIGHT :DEC.
(Reduced): The reduced temperature is maintained
during reduced periods. The circuit pump operates constantly.
4
NIGHT :STOP
(Stop): Heating is shut down during reduced
periods. When installation antifreeze is active, the reduced
temperature is maintained during reduced periods.
For circuits with a room sensor:
4
When the room temperature is lower than the room sensor set
point: The reduced temperature is maintained during reduced
periods. The circuit pump operates constantly.
4
When the room temperature is higher than the room sensor set
point: Heating is shut down during reduced periods. When
installation antifreeze is active, the reduced temperature is
maintained during reduced periods.
2
10
9
8
7
6
5
4
3
2
1
23
20
26
29
32
35
38
41
44
47
4
4
5
1
6
C
0
0
2
7
6
9
-A
00:00
00:00
00:00
6. Commissioning
AFC 18 - AFC 24 - AFC 30
120
09/07/2015 - 300026439-07