Code no. Description
Checking / solution
E06
The evaporator temperature sensor is short
circuited
Note: DHW production is handled by back-up if
back-up enabled
Bad connection
4
Check whether the sensor is connected
4
Check the link and the connectors
4
Check that the sensor has been correctly fitted
Sensor fault
4
Check the Ohmic value of the sensor
4
Replace the sensor if necessary
E07
The evaporator temperature sensor is open
Note: DHW production is handled by back-up if
back-up enabled
Bad connection
4
Check whether the sensor is connected
4
Check the link and the connectors
4
Check that the sensor has been correctly fitted
Sensor fault
4
Check the Ohmic value of the sensor
4
Replace the sensor if necessary
E08
Malfunction on the defrosting function
Note: DHW production is handled by back-up if
back-up enabled
4
Check activation of the defrosting solenoid valve
4
Check the position of the temperature sensor in the evaporator
4
Check that the fan is working correctly
4
Check that the condensates can flow freely
E09
The low pressure pressure switch alarm
sounds for more than 120 seconds
Note: DHW production is handled by back-up if
back-up enabled
4
Check the position of the temperature sensor in the evaporator
4
Check that the fan is working correctly
4
Check that the condensates can flow freely
E10
The low pressure pressure switch alarm has
been tripped more than 3 times during the last
24 hours
Note: DHW production is handled by back-up if
back-up enabled
4
Check the position of the temperature sensor in the evaporator
4
Check that the fan is working correctly
4
Check that the condensates can flow freely
4
Check the refrigerant load
9.2
Message and error history
The
Er bL 6
menu is used to consult the last 16 messages and the
last 16 errors displayed by the control panel.
1. Press once the
MENU
key. The
SE nS 1
menu is displayed.
2. Press the
)
key 5 times. The
Er bL 6
menu is displayed.
3. Press the
MODE
B
key to go to this menu.
Accessing the menu Menu Description
1x
)
Err
Error history
2x
)
bL
Blockage history
3x
)
CLr
Reset error and blockage history
C003203-E
1x
3
1
4
3
4
1
2
MENU
MODE
C004189-A
1
4
3
4
1
2
MENU
MODE
TWH 200E TWH 300E TWH 300EH
9. Troubleshooting
19/01/2015 - 300026515-001-05