4. Connect the 2 wires on the command module.
5. Put the control system module in place.
5.9
Electrical connections
5.9.1.
Recommendations
WARNING
4
Only qualified professionals may carry out electrical
connections, always with the power off.
4
Do not connect the power supply directly to the HP/
HC contact.
The earthing shall comply with local standards.
Power the appliance with a circuit that includes a 16 A omnipolar
circuit breaker, D curve type, with a gap of more than 3 mm.
The DHW tank is delivered with a 3G cable. If the power cable is
damaged, it must be replaced by the manufacturer, its after sales
service or persons with similar qualifications in order to obviate any
danger.
The electricity supply is connected to the mains by connection cable
(~230 V, 50 Hz) and electrical plug.
The HP/HC connection is made on the terminal block.
5.9.2.
Connecting the hydraulic back-up (Version
EH)
1. Remove the front cover.
¼
See chapter "Installing the control system in the living
room", page 35
4
5
C003407-D
5. Installation
TWH 200E TWH 300E TWH 300EH
38
19/01/2015 - 300026515-001-05
Содержание Kaliko TWH 200E
Страница 7: ...19 01 2015 300026515 001 05 5 ...
Страница 73: ...TWH 200E TWH 300E TWH 300EH 10 Spare parts 19 01 2015 300026515 001 05 71 ...
Страница 74: ...10 Spare parts TWH 200E TWH 300E TWH 300EH 72 19 01 2015 300026515 001 05 ...
Страница 75: ......