5.9.6.
Connection with timer programming and
photovoltaic signal
C004822-A
A
TEST
16 A
40 A
2 A
30
mA
L
N
X11-2 HP/H
PV-S
DC
AC
X11-1 LINE
C
3
5
6
4
4
3
AC type differential switch
4
Circuit breaker
5
Photovoltaic panel
6
Inverter
A
Power cable 1,5 mm
2
4
The heat pump and electrical backup are allowed to operate
depending on the time program.
4
The heat pump will start to heat at the temperature of 62 °C
(parameter
P07
) when the photovoltaic signal is actif.
4
If the photovoltaic signal is actif when the contact is open, set the
parameter
P04
on 3.
4
If the photovoltaic signal is actif when the contact is closed, set the
parameter
P04
on 4.
TWH 200E TWH 300E TWH 300EH
5. Installation
19/01/2015 - 300026515-001-05
43
Содержание Kaliko TWH 200E
Страница 7: ...19 01 2015 300026515 001 05 5 ...
Страница 73: ...TWH 200E TWH 300E TWH 300EH 10 Spare parts 19 01 2015 300026515 001 05 71 ...
Страница 74: ...10 Spare parts TWH 200E TWH 300E TWH 300EH 72 19 01 2015 300026515 001 05 ...
Страница 75: ......