4 Downloading/uploading data memory
4.1 Downloading data to an external memory unit (DOWNLOAD)
1. Scroll down the parameters with and keys until you visualize P011;
2. Press the key, the display visualizes the word “
” flashing;
3. Press the again and continue pressing it for 5 sec (if you release it before this period, the procedure is stopped);
4. Release the key as soon as the word “
” stops flashing;
All the control panel configurations (TYPE, parameters, remotes, operators stroke, etc..) are saved in the external memory unit;
Warning:
If there is any data in the external memory, during the memory download they will be overwritten.
5. At the end of the operation display returns to P011.
4.2 Uploading data from an external memory unit (UPLOAD)
1. Scroll down the parameters with and keys until you visualize P012;
2. Press the key, the display visualizes the word “
” flashing;
3. Press the again and continue pressing for 5 sec (if you release it before this period, the procedure is stopped);
4. Release the key as soon as the word “
” stops flashing;
All the control panel configurations (TYPE, parameters, remotes, operators stroke, etc..) contained in the external memory unit are
uploaded in the connected control panel;
5. At the end of the operation display returns to P012.
WARNING
If you are not connected to any external storage units or if the connecting cable is disconnected during the data transfer
operation, the display will visualize
, then the control unit is entirely reset and the display shows the word “TYPE” flashing.
Refer to the instruction of the external memory card to restore the operation of the control panel.
5
Inputs configuration
Where the installation requires different commands and / or additional to
the standard ones described by plan, you can configure each input for the
operation desired (eg. START, PHOTOS, STOP, etc ...).
1. Scroll down the parameters with the and to see that corresponding
to the desired one:
● P017=for INPUT 1;
● P018=for INPUT 2;
● P019=for INPUT 3;
● P020=for INPUT 4;
● P021=for INPUT 5;
● P022=for INPUT 6;
2. Confirm by pressing on the key to get access to the parameter (eg.
P018);
3. Scroll down with the and , keys to set the value corresponding to
the desired operation (refer to table “Input Configuration parameters” on
page 36);
4. Confirm by pressing on the key (display shows again P018).
5. Execute the new connection to the input just reconfigured.
6
Programming complete
WARNING
At the end of the programming procedure, use the buttons and until the appearance of the symbol “- - - - ”, the operator