ENGLISH
7
UTP / STP Connection Cable Wiring
The Local-Remote interconnection cable is terminated in RJ45 connectors and should
be wired according to the EIA/TIA 568 (Scheme B preferred) industry standard.
Pin
Wire Colour Wire Pair
1
White/Orange
T2
2
Orange/White
R2
3
White/Green
T3
4
Blue/White
R1
5
White/Blue
T1
6
Green/White
R3
7
White/Brown
T4
8
Brown/White
R4
The Voyager has been tested with all major makes of CAT 5 cable including BICC-
VERO, Mohawk, and AT&T. The Voyager has also been tested with most major
makes of CAT 5E/6 with good results.
Keyboard
•
The PC boots fine with no error messages, but the remote keyboard does not
work at all
a) Cable is loose, re-seat keyboard cable.
b) Wrong cable plugged in, keyboard and mouse cables reversed.
c) Try a different keyboard model. If the new keyboard works then the original one
may be incompatible (some older auto-sensing units may not work with this
product).
•
Wrong or missing characters from those typed.
a) The keyboard may be in the wrong mode.
b) Power down and reboot the entire system or
c) Try ctrl-alt-f12 from the remote unit
•
The PC always comes up with ‘Keyboard Error ’
a) If the system appears to work fine after pressing F1 (or ESC) adjust your BIOS set-
up so that the PC does not test the keyboard.
•
Connecting a keyboard to the unit affects the Video.
a) Change to a newer keyboard. Some older keyboards require a high current.
PS/2 Mouse
•
A mouse cursor on the screen, but the mouse does not work
a) Cable is loose, re-seat mouse cable and press ‘Scroll Lock’
b) Wrong cable plugged in, keyboard and mouse cables reversed.
TROUBLE