Chapter 3 - Printer Operation
29
Advanced Entry Calibration (continued)
Step
Action
Displayed Message
Comment
L
Use the buttons to set the Gain
Number determined in the
previous step. Press ENTER to
enable the setting.
TRAN SENSOR GAIN
yyy (0 - 31)
18
This example uses Gain Number
18.
M
Complete a table (see example
below) using new measurements,
as follows:
(A) Raise the Printhead Assembly.
Place the label over the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as P.
(B) Raise the Printhead Assembly.
Place the liner, notch, or mark
over the Media Sensor then lower
and latch the Printhead Assembly.
Record the sensor reading as G (or
M).
(C) Raise the Printhead Assembly.
Remove all media from the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as E.
TRAN SENSOR GAIN
yyy (0 - 31)
18
Where “yyy” is a numerical value
representing the current sensor
reading.
The re-sampled values may
differ from those previously
noted. This is normal; do not
readjust the Media Sensor.
Selected Gain Table
Gain Number
Paper
Gap (or Mark)
Empty
18 173 42 9
Содержание I-Class Mark II I-4212E/203
Страница 1: ...Operator s Manual...
Страница 2: ......
Страница 8: ...Chapter 1 Getting Started 2...
Страница 20: ...Chapter 2 Printer Setup 14...
Страница 38: ...Chapter 3 Printer Operation 32...
Страница 62: ...Chapter 4 Menu System 56...
Страница 76: ...Chapter 6 Troubleshooting 70...
Страница 80: ...Appendix A Specifications 74...
Страница 88: ...Appendix B Wireless and Wired LAN Setup 82...
Страница 94: ......