DATAMARS
R-IN 1300 MID User Manual – Rev
3.0
8 (40)
*sk[_]
Skip time slot on no response:
*sk0 skip on no response off
*sk1 skip on no response on (default)
*ct[_]
Collision threshold parameter:
*ct[0 .. 100] parameter from 0 to 100 (default 33, example *ct33)
*et [_]
Communication selection :
*et0 Ethernet
*et1 RS232
*et2 RS232 and Ethernet (default)
*br[_]
baud rate:
*br0 baud rate 9600
*br1 baud rate 19200
*br2 baud rate 38400
*br3 baud rate 57600
*br4 baud rate 115200 (default)
*cl[_]
Code length:
See Appendix A for more details.
*cl0 16 characters UIDs (standard, default)
*cl1 15 characters UIDs (Partial code)
*cl2 14 characters UIDs (Partial code)
*cl3 13 characters UIDs (Partial code)
*cl4 12 characters UIDs (Partial code)
*cl5 12 characters UIDs (First character special)
*cl6 11 characters UIDs (Partial code)
*cl7 10 characters UIDs (Partial code)
*cl8 9 characters UIDs (Partial code)
*cl9 8 characters UIDs (Partial code)
Attention: code maybe not unique with the selected code length
*tt[_]
Tag technology:
*tt1 tag technology ISO 15693(T-BT1320 T-BT1315) (default)
*tt2 tag technology Philips I-Code I (not available).
Example:
*tt1: only ISO
*tt2: only I-Code I
*tt12: both ISO and I-Code I
*if
Plots the current (TCP/IP) network configuration of the reader
including submask and default gateway
*ip[_-_-_-_]
Configure the IP (Internet Protocol) number of the reader.
Example:
*ip192-168-1-0
Sets the IP number 192.168.1.0
The default IP number of any new reader is 192.168.0.85
*ipsb[_-_-_-_]
Set the IP sub-mask associated to the local IP address:
Example:
*ipsb255-255-255-254 set the new sub mask for the eth0 IP
interface
*ipgw[_-_-_-_]
Set the IP address of the local gateway:
Example:
*ipgw192-168-1-201 set the gateway address to
192.168.1.201
To remove the default gateway: *ipgw0-0-0-0
*rg[_]
Receiver gain (in case of doubt, do not modify):
Amplification of the received signal.