CODING (SG4-P MODELS)
INSTRUCTION MANUAL 75
Code 1 or Code 2
When the user has to install two light curtains at a distance that is lower than the mini-
mum distance allowed from homologous devices (and has to have the RXs on the same
side), he has to configure the light curtains with different codes.
The configuration by means of GUI changes the code only on RX side; in order to have
the light curtain correctly working, the user has to configure TX side with the same code
by means of BCM.
Figure 63 - Code 1 or Code 2
The function can be set by BCM of both RX and TX devices. The number of available
codes is two:
Figure 64 - Normal operation (RX side): intercepted beams
Figure 65 - Normal operation (TX side)
Figure 66 - BCM Configuration: Coding Selection (TX and RX)
Figure 67ACM Configuration: Coding Selection