ACCESSORIES
118 SG4 EXTENDED
(SG-M-CB) CONNECTION BOX
The SG-M-CB Connection box is part of SG-M accessories for Muting, to be used with
Datalogic safety light curtains of SG series, with integrated muting function (e.g. SG
BODY REFLECTOR MUTING).
Muting sensors can be connected to SG-M-CB Connection box via M12 cables.
The signals are connected to safety light curtain dedicated muting connector via approx.
0.5m long pigtail cable with M12 female connector.
Aside from the green LEDs
1
(to indicated sensors output status), the SG-M-CB does not
contain any electronic elements and is therefore not subject to any safety classification.
Features:
•
Supply and switching v24Vdc
•
M12 connection
•
Simple connection to safety light curtains
Figure 46 - Connection box
1. For correct operation of LED indicators, it is mandatory to connect identical sensors to the four
M12 sockets.