
RESET
active on high level in failure lockout
RESTART
active on high level at runtime
ALIGNMENT
active on high level at startup
OVERRIDE
active on high level at runtime
OVERRIDE 2
active on low level at runtime
EDM
must be OSSDs antivalent at runtime with
EDM enabled
MUTING DISABLE
Muting disabled on high level at runtime
OSSD 1 /
OSSD 2
high level = free path
low level = object detection
OVERRIDE
STATUS
high level = override function active
low level = override function not active
NB: at start-up there are fluctuations on
this line not concerning the override acti-
vation
MUTING LAMP
open collector sinks on Muting activation
MUTING 1 / MUT-
ING 2
active on high level at runtime
EARTH
connect directly to earth
ELECTRICAL CONNECTIONS
24 SG4 EXTENDED
MUTING CONFIGURATION RECEIVER SG4-P
LINE
LAYOUT
CONNECTION
BEHAVIOR
Содержание SG4 FIELDBUS Series
Страница 1: ...SG4 Extended INSTRUCTION MANUAL Safety Light Curtains ...
Страница 8: ...VIII SG4 EXTENDED COMPLIANCE ...
Страница 10: ...X SG4 EXTENDED GENERAL VIEW Figure 1 Safety Light Curtain ...
Страница 123: ...DOUBLE MUTING ARMS INSTRUCTION MANUAL 113 Light curtain Active Passive Arms L Light curtain Active Passive Arms T ...
Страница 133: ......
Страница 134: ......
Страница 135: ......