OVERRIDE FOR SG4-N
INSTRUCTION MANUAL 67
Reduced resolution
Reduced Resolution is a particular kind of floating blanking in which more than one
object can intercept each a defined number of beams with the ESPE remaining in nor-
mal operation.
The number that follows indicates how many adjacent beams can be intercepted by the
object to allow the light curtain to remain in Normal Operation. For example, with
Reduced Resolution 2 the object intercepts 1, 2 or no beams and the light curtain
remains in Normal Operation.
This function can be set only by means of ACM.
NOTE
Figure 51 - Reduced resolution
Dimension
This value indicates the size of blanking zone.
This function can be set only by means of ACM.
Position
This value indicates the first beam of the blanking zone, starting from the bottom of the
ESPE (the bottom of the ESPE is the side with the LEDs and the push buttons).
Since in floating blanking configuration zones haven't a fixed position, it is valid only in
fixed blanking.
This function can be set only by means of ACM.
This function affects the effective resolution of the light curtain and the
user is warned about it.