(SG-M) MUTING ARMS WITH EXTERNAL SENSORS
INSTRUCTION MANUAL 117
Mounting
•
Put the arm slider (1) into the column slot (2).
•
Fix the arm (3) in the desired position by screws (4), 1 Nm recommended tighten-
ing torque.
Figure 43 - Phase 1
•
Rotate sensors/reflectors support (5) in the desired position; if necessary, trans-
late support removing and spacing cable-locker (6) and fix by screws (7), 2 - 3 Nm
recommended tightening torque.
Figure 44 - Phase 2
•
Loosen the two screws (8) and rotate/set the sensor/reflector as desired; then fix
by screws (8), 1 Nm recommended tightening torque.
NOTE
Figure 45 - Phase 3
For electrical link of SG-M kit to Datalogic safety curtains the use of Data-
logic Connection ox SG-M-CB is recommended.
For each muting system kit the use of the same sensor type is recom-
mended. Sensors must be set on Dark Mode.