FUNCTIONS SETTING
36 SG4 EXTENDED
Reset to factory configuration
System Integrator User can reset ESPE at factory configuration settings with SG
Extended GUI software with the following action:
Figure 4 - Task selection
Figure 5 - Device selection and erase configuration
Figure 6 - Insert password
Only if there is no ACM configuration on light curtains, user can also reset ESPE at fac-
tory configuration settings with the following push button action:
•
press and keep pressed CONFIRM button for at least 9 sec. (but less than 30 sec.
otherwise the light curtain goes in lockout failure)
•
LEDs blink for a while, then the light curtain resets
•
after reset the light curtains begins its normal functioning with the factory config-
uration
NOTE
Password is requested only from GUI version 1.3.0 and firmware version
6.1.0.