FUNCTIONS SETTING
34 SG4 EXTENDED
ADVANCED CONFIGURATION MODE (SG4-P)
SG Extended GUI software (Graphic User Interface, GUI) for PC allows the user to set
ESPE advanced configuration. Many parameters are available to customize ESPE behav-
ior for specific applications.
Since ESPE parameters can be safety critical and PC software cannot be guaranteed as a
safety component, a safe configuration procedure has to be followed.
Configuration procedure on GUI can be done by authorized personnel only. Such per-
sonnel must be sure that protected dangerous machine has no access during configura-
tion procedure.
There are 3 different kinds of operator that can use the GUI with 3 different levels of
authorizations.
System Integrator
: has all the possible authorizations and can set every configuration
on the GUI
Maintainer
: can upload the configurations (saved on the GUI) on the light curtain and
use the GUI for monitoring the system, but he can't create new configurations
Machine Operator
: uses the GUI only for monitoring the system
Depending on the kind of operator there are different passwords that protect some
functions of the GUI.
System Integrator
SystemIntegrator
Maintainer
Maintainer
Machine Operator
no password requested
Figure 2 - ACM configuration cycle
Device selection
: user selects ESPE to configure, choosing among devices on network
identified by a unique Serial Number
Parameters selection
: user, after setting the configuration ESPE, requires the transfer at
the GUI and insert the password to access the device. The GUI sends the configuration
command, ESPE switches to SAFE state, a “configuration in progress” indication is
shown on ESPE led interface, old configuration on ESPE is erased
Report check
: ESPE sends back to GUI the received configuration, GUI produces a print-
able SAFETY REPORT with all safety related information about configuration in progress
(see Figure 3).
After checking all report contents user can accept configuration: ESPE restarts in normal
operation with the new configuration.
OPERATOR
PASSWORD
Содержание SG4 FIELDBUS Series
Страница 1: ...SG4 Extended INSTRUCTION MANUAL Safety Light Curtains ...
Страница 8: ...VIII SG4 EXTENDED COMPLIANCE ...
Страница 10: ...X SG4 EXTENDED GENERAL VIEW Figure 1 Safety Light Curtain ...
Страница 123: ...DOUBLE MUTING ARMS INSTRUCTION MANUAL 113 Light curtain Active Passive Arms L Light curtain Active Passive Arms T ...
Страница 133: ......
Страница 134: ......
Страница 135: ......