RESET
active on low level in failure lockout
RESTART
active on low level at runtime
ALIGNMENT
active on low level at startup
OVERRIDE
refer to "
Override for SG4-N" on page 62
EDM
See "
must be OSSDs antivalent at runtime with
EDM enabled
OSSD 1 /
OSSD 2
high level = free path
low level = object detection
MUTING LAMP
open collector sinks on Muting activation
MUTING 1 /
MUTING 2
active on high level at runtime
RESET
active on high level in failure lockout
RESTART
active on high level at runtime
ALIGNMENT
active on high level at startup
TOLERANCE
active on high level at startup
TEACH-IN
active on high level at runtime
EDM
See "
must be OSSDs antivalent at runtime with
EDM enabled
OSSD 1 /
OSSD 2
high level = free path
low level = object detection
BLANKING LAMP
open collector sinks on Blanking activation
EARTH
connect directly to earth
PIN-OUT AND CONFIGURATION PIN CONNECTION
INSTRUCTION MANUAL 25
MUTING CONFIGURATION RECEIVER SG4-N
LINE
LAYOUT
CONNECTION
BEHAVIOR
BLANKING CONFIGURATION RECEIVER SG4-P
LINE
LAYOUT
CONNECTION
BEHAVIOR