52
Electrical Installation
AccuLazr™ AL5010 Product Line Manual
Output Module Application
Shown below is a typical output module application. When connecting high
impedance loads, you may need to add a resistor in parallel with the load.
This resistor (typically 300 to 6,000 ohms) provides a continuous minimum
current flow (10 mA DC or 50 mA AC) through the output module in the
closed state.
-
+
AC or DC Source
Optional Resistor
Fuse
Recommended
Load
-
Output Module TB
+
Optional Resistor for High Impedance Loads
Back Electromotive Force (EMF)
is sometimes generated when an
inductive load is switched off. Back EMF may damage the output module. A
diode in parallel with the inductive device dissipates the back EMF.
-
+
DC Source
Optional Diode
Fuse
Recommended
Inductive
Load
-
Output Module TB
+
Optional Diode to Dissipate Back EMF
An example output module application is the use of a Stack Light. The
AL5010 would use three output modules to send signals to the stack light to
visually indicate specific conditions (e.g., green = read, yellow = multiple
codes, red = no read).
(See drawing in Appendix F.)
Input Module Application
Input module 1000056135 is most often used for an End Trigger Photoeye
application.
(See drawing 113490 sheet 3 in Appendix F.)
NOTE:
Any other input module application requires custom software.
Contact Accu-Sort Customer Service for more information.
Accu-Sort Systems, Inc.
04-AL5010_Electrical_Installation_R20.doc
Содержание AccuLazr AL5010
Страница 1: ...AL5010 Product Line Manual ...
Страница 140: ...132 Service AccuLazr AL5010 Product Line Manual Accu Sort Systems Inc 09 AV5010_Service_R20 doc Notes ...
Страница 226: ......
Страница 227: ......
Страница 237: ......
Страница 238: ......
Страница 239: ......
Страница 240: ...www datalogic com ...