124 Troubleshooting
AccuLazr™ AL5010 Product Line Manual
ForcedTx
Forced Transmit (non-tracking). A forced transmit indicates
that the start of trigger occurred before the specified transmit
delay time had expired.
Lost Codes
Lost Codes (tracking). If a bar code cannot be placed onto
any package while in tracking, the code is “lost” and this
counter is incremented. Lost codes are also reported in the
AL5010 Monitor message window. Lost code occurances
typically indicate tracking parameters need to be adjusted.
Missed Tx
Missed Transmit (tracking). If a bar code is decoded after
the message for that package has been transmitted, the
Missed Transmit counter is incremented.
Decode/DSP Counters
Decode/DSP
Counters
Description
DSP Codes
Count of the number of barcodes decoded, per laser, by the DSP.
Scan Ints
Number of scan interupts detected by the DSP.
Queue Size
Current size of the scan data queue within the DSP. This value
changes dynamically.
Num Cluster
Current number of DRX clusters in use by the DSP. This value
changes dynamically.
Bad Scan
Count of the number of scans in which the data contained
formatting errors.
Pipe Error
Count of internal errors on the transfer of scan data from the scan
data buffer.
Full Scans
Number of times a scan could not be added to the scan data
buffer because the maximum number of scans was exceeded.
Mem Full
Number of times a scan could not be added to the scan data
buffer because the memory was full.
ScanTooLong Number of times a scan was skipped because it contained too
many transitions.
Max Clusters
Number of times, the maximum number of DRX clusters was
exceeded.
ARM and DSP Restarts Counters
Description
ARM Restarts Number of times the ARM processor has restarted. This typically
means the hardware watchdog timer expired causing the ARM
processor to restart.
DSP Restarts Number of times the DSP processor has been restarted.
Typically, this happens if the ARM suspects the DSP has “locked
up” for any reason.
Accu-Sort Systems, Inc.
08-AL5010_Troubleshooting_R20.doc
Содержание AccuLazr AL5010
Страница 1: ...AL5010 Product Line Manual ...
Страница 140: ...132 Service AccuLazr AL5010 Product Line Manual Accu Sort Systems Inc 09 AV5010_Service_R20 doc Notes ...
Страница 226: ......
Страница 227: ......
Страница 237: ......
Страница 238: ......
Страница 239: ......
Страница 240: ...www datalogic com ...