AccuLazr™ AL5010 Product Line Manual
Electrical Installation 47
Trigger Connections
The AL5010 supports three trigger modes: hardware, software, and
continuous. When using hardware trigger, one or more input signals “trigger”
the reader. Software trigger is accomplished by sending a specific ASCII
message via serial or network communications. Continuous trigger requires
no external trigger.
When a hardware trigger (i.e., package detector) is required, Accu-Sort’s
retro-reflective photoeye (PN 100020569) is recommended.
Wiring Trigger to the Enhanced Interface Module
Connect trigger wiring to the interface module terminal blocks.
Wire the Accu-Sort photoeye as shown below.
Enhanced Interface Module
Basic Interface Module
In applications using a photoeye other than the Accu-Sort standard, follow
the TRIGGER wiring table to assure proper wiring. The trigger must be able
to operate using the +24V DC source (24V) and not draw more than 100mA.
The trigger input must be able to sink (or source) 10mA at +24V DC.
NOTE:
To confirm the Trigger photoeye is functioning properly, watch the
Trigger LED while the photoeye’s beam is blocked.
(See Chapter 5 for
details.)
The Accu-Sort photoeye also includes a status LED.
Multiple Readers
In controller/client applications, wire the trigger photoeye
to the AL5010 set up as the controller.
(See drawing in Appendix F.)
04-AL5010_Electrical_Installation_R20.doc
Accu-Sort Systems, Inc.
Содержание AccuLazr AL5010
Страница 1: ...AL5010 Product Line Manual ...
Страница 140: ...132 Service AccuLazr AL5010 Product Line Manual Accu Sort Systems Inc 09 AV5010_Service_R20 doc Notes ...
Страница 226: ......
Страница 227: ......
Страница 237: ......
Страница 238: ......
Страница 239: ......
Страница 240: ...www datalogic com ...