AccuLazr™ AL5010 Product Line Manual
Maintenance
107
7 Maintenance
This chapter provides instructions for maintaining optimum performance and
life for your AL5010. It provides specific information on:
Maintenance Procedures
Exterior Cleaning
Mounting Hardware Checks
Wiring Connection Checks
Tools and Materials Required
Item
Description
Soft-bristle brush
For cleaning the reader’s exterior
Clean soft cloths
For cleaning the reader’s exterior
Mild detergent solution for cleaning the reader’s exterior.
Cleaning solutions
70% denatured alcohol, 30% de-ionized water solution for
cleaning exit window
Soft cotton swabs
or lint-free cloth
Use to clean reader’s exit window
Laser Shutoff Procedure
In order to perform certain maintenance and service tasks, the reader’s
lasers must be shut off in order to comply with all laser safety requirements.
To shutoff the lasers:
1. Press the
Test/Diagnostics
button (
!
) for 5 seconds.
2. The bar graph LEDs will light for the 5 second duration and then go out.
3. The lasers will then shut off.
4. After maintenance or service is complete, repeat the process to turn the
lasers back on.
AL5010 Button and LEDs involved with Laser Shutoff
07-AL5010_Maintenance_R20.doc
Accu-Sort Systems, Inc.
Содержание AccuLazr AL5010