Power Supply Connection
Use the PG-120 power Kit (3 versions for European, UK or US plug) and CAB-PG-0002
+ BA400 connector to connect the PG-120 to the CBX. An alternative power supply to the
PG-120 is the PWR-120.
•
CBX Connection
Use CAB-SCSxx between the A30 camera and the CBX for power, external trigger
device (photocell), and additional I/O connections.
Use the CAB-GE0x for the Gigabit Ethernet connection to the host.
NOTE
The
A30
does not support sourcing power towards the CBX in order to
power I/O devices. These devices must be powered through the CBX or
from an external source.
CAUTION
Do not connect GND and SGND to different (external) ground references.
GND and SGND are internally connected through filtering circuitry which
can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
INDICATORS AND KEYPAD BUTTON
Figure 2 - Indicators
The following LED indicators are located on the camera (Figure 2):
1
POWER
On – camera is connected to power
2
NET
On – Ethernet link is established. Blinking - data transmission
3
BUSY
LED blinks during task execution and flash memory access
4
OUT
1
On – Output 1 is on
5
OUT
2
On – Output 2 is on
6
OUT
3
On – Output 3 is on
7
ONLINE
On – Loaded tasks will be executed based on their trigger parameters
8
BUTTON
Camera Reset: See Note below
Camera Button event: Press and release the button (Internal software event
trigger only)
Note: Camera Reset restores the factory camera settings including deleting all user settings
and resetting the camera’s Mask and IP Address to the factory default (192.168.0.128).
To Reset the Camera
1. Turn off camera power.
2. Press and hold the Camera Reset button.
3. Turn on power. Continue pressing the Camera Reset button.