INPUTS
17
INPUT 2 CONNECTIONS
INPUT 2 CONNECTIONS USING CBX POWER
CAUTION
Power is available directly to the Input Device, independently from the
Power Supply Switch inside the CBX.
Figure 15 - PNP Input 2 Using CBX Power
Figure 16 - NPN Input 2 Using CBX Power
INPUT 2 CONNECTIONS USING EXTERNAL POWER
Camera
INPUT DEVICE
Vext 30 Vdc max.
D
E
V
CC
~
~
+ -
V
Signal
I2A
I2B
I
in
Figure 17 - PNP Input 2 Using External Power
Camera
INPUT DEVICE
Vext 30 Vdc max.
D
E
Signal
V
V
CC
~
~
+ -
I2A
I2B
Figure 18 - NPN Input 2 Using External Power
CBX500
Function
+V
Power Source - Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
-V
Power Reference - Inputs