COMPLIANCE 

iv 

 

 

COMPLIANCE 

For installation, use, and maintenance, it is not necessary to open the camera. 

Opening the camera will void the warranty. 

 

Connect Ethernet and dataport connections to a network which has routing only 

within the plant or building and no routing outside the plant or building. 

EAC COMPLIANCE 

Customs Union: 

The CU Conformity certification has been achieved; this allows the Product to bear 

the Eurasian mark of conformity. 

EMC COMPLIANCE 

In order to meet the EMC requirements: 

  connect the camera chassis to the plant earth ground by means of a flat copper braid 

shorter than 100 mm; 

  for CBX connections, connect the pin "Earth" to a good Earth Ground; 

  for direct connections, connect the main interface cable shield to pin K of the 19-pin 

connector. 

POWER SUPPLY 

ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT 

 

This product is intended to be installed by Qualified Personnel only. 

 

This product is intended to be connected to a UL Listed Direct Plug-in Power Unit 

marked LPS or “Class 2”, rated 10-30Vdc 1-0.33A. 

CE COMPLIANCE 

CE marking states the compliance of the product with essential requirements listed in 

the applicable European directive. Since the directives and applicable standards are 

subject to continuous updates, and since Datalogic promptly adopts these updates, 

therefore the EU declaration of conformity is a living document. The EU declaration 

of conformity is available for competent authorities and customers through Datalogic 

commercial reference contacts. Since April 20th, 2016 the main European directives 

applicable to Datalogic products require inclusion of an adequate analysis and 

assessment of the risk(s). This evaluation was carried out in relation to the applicable 

points of the standards listed in the Declaration of Conformity. Datalogic products are 

mainly designed for integration purposes into more complex systems. For this reason 

it is under the responsibility of the system integrator to do a new risk assessment 

regarding the final installation. 

WARNING 

This is a Class A product. In a domestic environment this product may cause radio 

interference in which case the user may be required to take adequate measures. 

FCC COMPLIANCE 

Modifications or changes to this equipment without the expressed written approval of 

Datalogic could void the authority to use the equipment. 

This device complies with PART 15 of the FCC Rules. Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference, and (2) 

this device must accept any interference received, including interference which may 

cause undesired operation. 

Содержание A30

Страница 1: ...A30 QuickStart Guide Publication 821002024 Rev D...

Страница 2: ...c S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U Impact P Series Vision Program Manager VPM P...

Страница 3: ...llowing patents Utility patents EP0996284B1 EP0999514B1 EP1014292B1 EP1128315B1 EP1396811B1 EP1413971B1 JP4435343B2 JP4571258B2 US6512218 US6616039 US6808114 US6997385 US7053954 US7387246 US8058600 US...

Страница 4: ...cable standards are subject to continuous updates and since Datalogic promptly adopts these updates therefore the EU declaration of conformity is a living document The EU declaration of conformity is...

Страница 5: ...when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual...

Страница 6: ...used A strobe or other external illuminator may be required CAUTION The camera must be disconnected from the power supply during this procedure 1 In a dust free environment remove the Camera Lens Cov...

Страница 7: ...the Impact Reference Guide for programming details Connect the System In the typical standalone layout shown in the figure below an EtherNet host is connected to the camera The camera can use an exter...

Страница 8: ...permanently damaged if subjected to voltage drops over 0 8 Vdc INDICATORS AND KEYPAD BUTTON Figure 2 Indicators The following LED indicators are located on the camera Figure 2 1 POWER On camera is co...

Страница 9: ...ave turned on and remain lit release the Camera Reset button 7 Wait approximately 30 seconds for the camera to restart MECHANICAL DIMENSIONS The A30 can be installed to operate in different positions...

Страница 10: ...A30 QUICKSTART GUIDE 10 Figure 4 Mounting Bracket Overall Dimensions mm in...

Страница 11: ...ing brackets you can obtain rotation on the various axes of the camera as shown in the diagrams below Figure 5 Positioning with Body Mounting Bracket Back Figure 6 Positioning with Body Mounting Brack...

Страница 12: ...es I O Block Terminal Name Function 9 13 Vdc Power supply input voltage 7 25 GND Power supply input voltage 18 I1A External Trigger or polarity insensitive 19 I1B External Trigger or polarity insensit...

Страница 13: ...ernal Trigger V Power Source Inputs I2A Input 2 or polarity insensitive I2B Input 2 or polarity insensitive I3A NOT USED I4A NOT USED I34B NOT USED V Power Reference Inputs Shield Shield Network Cable...

Страница 14: ...X Installation Manual for details RS232 SERIAL INTERFACE The signals relative to the following serial interface types are available on the CBX spring clamp terminal blocks The serial interface paramet...

Страница 15: ...nds This value can be increased through the software parameter Debounce Filter Refer to the Camera Setup tab section in the Impact Reference Guide for further details These inputs are optocoupled and...

Страница 16: ...igger Using CBX Power EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER Camera EXTERNAL TRIGGER Vext 30 Vdc max A B VCC V Signal I1A I1B I in Figure 13 PNP External Trigger Using External Power...

Страница 17: ...ure 16 NPN Input 2 Using CBX Power INPUT 2 CONNECTIONS USING EXTERNAL POWER Camera INPUT DEVICE Vext 30 Vdc max D E VCC V Signal I2A I2B I in Figure 17 PNP Input 2 Using External Power Camera INPUT DE...

Страница 18: ...iscrete Output tool section in the Impact Reference Guide for further details OUTPUT CONNECTIONS USING CBX POWER Note The strobe signal connection is shared with Output 3 If a non zero value is define...

Страница 19: ...d to the Vdc and GND terminal clamps The strobe signal connection is shared with Output 3 If a non zero value is defined for the Strobe Pulse Length value in VPM Impact General the strobe is active If...

Страница 20: ...Turn on the Laptop or PC that will be used for configuration connected to the Ethernet port of the A30 camera 2 You may need to turn off automatic virus checking during the install if it causes insta...

Страница 21: ...Right click Local Area Connection LAN1 or LAN2 and select Properties 3 On the General tab select Internet Protocol TCP IP and click Properties 4 On the General tab select Use the following IP address...

Страница 22: ...nection or LAN1 or LAN 2 and select Properties 5 In the list of items select Internet Protocol Version 4 TCP IPv4 then click Properties 6 Select Use the following IP address 7 Enter the desired IP add...

Страница 23: ...ames sec ENVIRONMENTAL FEATURES Operating Temperature 1 0 to 45 C 32 to 113 F Storage Temperature 20 to 70 C 4 to 158 F Max Humidity 90 non condensing Vibration Resistance EN 60068 2 6 14 mm 2 to 10 H...

Страница 24: ...www datalogic com...

Отзывы: