A30 QUICKSTART GUIDE
16
EXTERNAL TRIGGER
Camera
Signal
B
C
A
L
Ground
V
V
CC
~
~
+ -
Vdc
GND
I1A
I1B
Figure 12 - NPN External Trigger Using CBX Power
EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER
Camera
EXTERNAL TRIGGER
Vext 30 Vdc max.
A
B
V
CC
~
~
+ -
V
Signal
I1A
I1B
I
in
Figure 13 - PNP External Trigger Using External Power
Camera
EXTERNAL TRIGGER
Vext 30 Vdc max.
A
B
Signal
V
V
CC
~
~
+ -
I1A
I1B
Figure 14 - NPN External Trigger Using External Power