A30 QUICKSTART GUIDE
14
POWER SUPPLY
NOTE
The A30 does not support sourcing power towards the CBX through the
CBX "power from device" source jumper setting. Power must be supplied to
the CBX as shown below.
To power the camera and/or I/O devices through the CBX, power must be supplied to the
CBX500 spring clamp terminal pins as shown in Figure 9:
Figure 9 - Power Supply Connections
The power must be between 10 and 30 Vdc only.
It is recommended to connect the device CHASSIS to earth ground (Earth) by setting the
appropriate jumper in the CBX connection box. See the CBX Installation Manual for details.
RS232 SERIAL INTERFACE
The signals relative to the following serial interface types are available on the CBX spring
clamp terminal blocks.
The serial interface parameters (baud rate, data bits, etc.) are defined in Vision Program
Manager (VPM) software. Refer to the Serial Port section of the Impact Reference Guide
(Publication # 843-0093).
The following pins are used for RS232 interface connection. The Impact software does not
support hardware (CTS/RTS) or software (Xon/Xoff) data flow control.
CBX500
Function
TX
Transmit Data
RX
Receive Data
SGND
Signal Ground
It is always advisable to use shielded cables. The overall maximum cable length must be
less than 15 m (49.2 ft.).
Figure 10 – RS232 Main Interface Connections Using Hardware Handshaking
Содержание A30
Страница 1: ...A30 QuickStart Guide Publication 821002024 Rev D...
Страница 10: ...A30 QUICKSTART GUIDE 10 Figure 4 Mounting Bracket Overall Dimensions mm in...
Страница 24: ...www datalogic com...