EXTERNAL ILLUMINATORS
19
OUTPUT CONNECTIONS USING EXTERNAL POWER
Figure 21 - Output Open Emitter Using External Power
Figure 22 - Output Open Collector Using External Power
EXTERNAL ILLUMINATORS
If an External Illuminator (strobe light) is used, it can be powered from the CBX connection
box. It must be connected to the
Vdc
and
GND
terminal clamps. The strobe signal
connection is shared with Output 3. If a non-zero value is defined for the Strobe Pulse Length
value (in VPM – Impact – General), the strobe is active. If the value is zero, Output 3 is
active.
CAUTION
Power is available directly to the strobe, independently from the Power
Supply Switch inside the CBX.
Configure the Strobe Signal in the VPM software. Refer to the Camera Setup tab section of
the Impact Reference Guide.
Figure 23 – External Illuminator Connections