A30 QUICKSTART GUIDE
12
TERMINAL BLOCK ELECTRICAL CONNECTIONS
Camera power, trigger signals, and strobe triggers can be connected to the camera using a
CBX500 connection box, terminal block and cable, or an unterminated cable. To use a
terminal block (95A906346) you must also use the optional camera cable (CAB-SCSxx).
The
camera cannot source power through this connector
.
We recommend making system connections through a CBX connection box since it offers
the advantages of easy connection, easy device replacement, and filtered reference signals
(see page 13).
Figure 8 – A30/T4x-Series I/O Block
Terminal
Name
Function
9 & 13
Vdc
Power supply input v
7 & 25
GND
Power supply input voltage -
18
I1A
External T or -
(polarity insensitive)
19
I1B
External T or -
(polarity insensitive)
6
I2A
I2: Input 2 + or - (polarity insensitive)
10
I2B
I2: Input 2 + or - (polarity insensitive)
22
O1-
Output 1 -
11
O2+
Output 2 +
8
O1+
Output 1 +
12
O2-
Output 2 -
2
TX
RS232 Transmit
3
RX
RS232 Receive
4
Not Used
Not Used
5
Not Used
Not Used
21
Not Used
Not Used
20
Not Used
Not Used
17
Strobe-/O3B
Strobe - / Output 3 –
(See Note Below)
16
/O3A / Output 3 +
1
CHASSIS
Cable shield
Note: The strobe signal connection is shared with Output 3. If a non-zero value is defined for the Strobe Pulse
Length value (in VPM – Impact – General), the strobe is active. If the value is zero, Output 3 is active.