■ Running a Job on PSV7000 ◘ List of Steps to Start a Job
PSV7000 Operator’s Manual
—43—
back
Figure 25: If a Retaining Clip was used, remove it from the probe prior
to pulling off the tip.
8.
Pull down on the probe tip to pull it off the probe holder. Some
have rubber cups on the end—don’t lose it.
9.
Referring to the
PNP Head Probe Tips
table on
page 38,
select the
correct probe tip, or tip + rubber cup. Assemble as required by
pushing the rubber cup onto the square at the end of the tip.
10. Insert the selected probe, aligning the oval flange with the slot in
the probe base.
Figure 26: The tip must seat in the slot in the holder.
The Retaining Clip has not been installed yet in this
view.
11. (Optional but suggested) Insert the Retaining Clip, pushing it on
making sure the aligning pin doesn’t interfere.
12. Make sure the tip is clean.
13. Repeat with the second probe if necessary.
14. Still at the
Run
window, right-click the head >
Tip Change Done
.
(This finds the center of probe rotation, or COR.)
Fixed Aligning pin
on Probe Holder
Retaining Clip
(shown gold here)
Probe Tip
Pull
Pull