Adjust screen contrast for 
daytime/nighttime viewing  

Swipe to the Settings page. Select TCU Settings. Tap the 
entry to the right of Theme Mode and select either Day Mode 
or Night Mode. 

 

Maintenance 

The TCU itself is designed for a minimum amount of maintenance. It is more important to maintain the 
station and the components connected to the TCU. 

When cleaning the TCU's front panel, use a microfiber cloth with LCD screen cleaner (similar to that which 
you would use for a computer monitor or television screen). Do not use solvents to clean the TCU's front 
panel. 

Recommended Backup Batteries 

 

12V, 7.0Ah Rechargeable Battery (Part No. DFS-00363-008-01) 

 

12V, 2.6Ah Rechargeable Battery (Part No. DFS-00363-008-02) 

The  TCU800  includes  one  replaceable  fuse.  If this  fuse  should  fail,  replace  it  with  a  new  identical  one 
(0312002.MXP) (Part No. DFS-040-0079). 

Replacement Parts 

Parts  should  only  be  replaced  with  parts  recommended  and  approved  by  Data  Flow  Systems.  Placing 
unapproved parts in the TCU voids the safety certification. See the Return Authorization (RA) Procedure 
(next section) for instructions on obtaining replacement parts. 

Return Authorization (RA) Procedure 

In the event that a unit fails, during or after the warranty period, it may be returned to Data Flow Systems 
to be repaired or replaced. 

All RA's will be subject to standard shipping and handling charges. Minimum handling charges will be 
assessed in most cases for work such as Radio Tuning, Backplanes, "No Problem Found," and other minor 
repairs. Handling charges will be waved on warranty equipment. Standard shipping charges will be based 
on UPS ground, please advise if other arrangements are needed (UPS Red, FedEx, Pickup, Freight…). The 
standard cost of repairs and shipping charges can be obtained by contacting our RA Department by phone 
or e-mail. 

STEP 1:

 Replace the failed unit with a spare one of the same type, if available. 

STEP 2:

 Contact Data Flow Systems Inc. to receive an RA# via: 

 

Email DFS at [email protected]

 

Call DFS at 321-259-5009 ext. 1117 during normal operating hours. 

The following information must be provided. 

 

Customer/Utility Name and Ship to Address 

 

Contact Name and Phone Number 

 

Products to be returned and Serial Numbers 

 

Detailed description of failure 

 

PO# 

 

Содержание TCU800

Страница 1: ...T C U 8 0 0 Q u i c k S t a r t G u i d e Data Flow Systems Inc...

Страница 2: ...ation contained in this document are welcomed Data Flow Systems Inc also reserves the right to make changes to the specifications of the Telemetry Control Unit and to the information contained in this...

Страница 3: ...nd other manuals can be found on Data Flow Systems web site at www dataflowsys com This information is provided for qualified personnel only Improper installation service or maintenance can cause prop...

Страница 4: ...ariety of automated tasks when interfaced with other telemetry equipment DFS equipment or RS 485 or RS 232 Modbus compatible devices When used as a programmable device the TCU800 can control up to 6 d...

Страница 5: ...touchscreen and overlay push button H O A Switches 3 x 3 position switches for Hand Off Auto operation Environmental Conditions Ambient Operating Temperature Range 10 C to 60 C 14 F to 140 F The upper...

Страница 6: ...s to remotely monitor off site conditions and control equipment from a central location Mounting options allow the TCU to be mounted to a front panel or mounted flush against or stood off from the bac...

Страница 7: ...motor starter 1 relay 120 240VAC 60HZ 1A Pilot Duty P1 24 STRT_PWR Line side of motor starter relays 120 240VAC 60HZ 3A Top Rear Connector P3 Pump Controller Mode PIN Name Description Electrical Rati...

Страница 8: ...RUN Motor 3 run digital monitor input 10 30VAC DC 10mA P2 4 EXT_PM External phase monitor digital input 10 30VAC DC 10mA P2 5 IN_COM_1 Common return for motor run and external phase monitor input 10 3...

Страница 9: ...y connected to EARTH Cable shield for RS 485 or RS 232 Ground P4 6 EX_GND_RAD RS 232 signal ground 24V Not Rated P4 7 RTS_RAD RS 232 Request to send 24V Not Rated P4 8 EX_TXD_RAD RS 232 transmit data...

Страница 10: ...harm delicate components inside the TCU To prevent static damage put on an electrostatic discharge wrist strap before touching any of the TCU s electronic components In addition to the preceding preca...

Страница 11: ...hat prevents access to live parts without a tool Attention should be given to the location of the TCU to provide accessibility for wiring and servicing Leave enough space around the TCU to access the...

Страница 12: ...lable when a TCU is replacing a rear panel mounted PCU It uses the preinstalled PCU mounting bracket and brings the TCU to the same level as the PCU it is replacing This option uses the Retro installa...

Страница 13: ...to the unit The first option uses the Spring Clamp Connector Tool which can be ordered from DFS See the TCU800 Installation and Operation Manual for information on ordering connectors and the connect...

Страница 14: ...tes from 120 VAC Verify the input voltage on the TCU s connector label before wiring Three terminals are provided for wiring power P1 5 AC_PWR AC power P1 6 AC_NEUT AC neutral P1 7 TGND earth ground T...

Страница 15: ...to the TCU800 Installation and Operation Manual which can be found on the DFS website www dataflowsys com Home Button and Power Indicator Press and hold the TCU s home button to turn the unit on or en...

Страница 16: ...left or right After swiping the screen will turn black and display the new screen in a moment In order to configure the TCU800 tap on the text and numbers in order to adjust their values When you tap...

Страница 17: ...t and communicate with the central computer or server via its integrated radio or network interface Using the TCU in conjunction with a radio based telemetry system requires that you obtain an FCC lic...

Страница 18: ...Off Time Display Touch Gestures Async Baud Lead Off Level Start Fault Alarm Debug Logging Dash Number Flow EQ Stop Fault Alarm GBL MOD DLY Low Level Auto Retry GBL FIX DLY XDCR 2 Low Cal Point BEM Mod...

Страница 19: ...upload it to the appropriate station you want to auto config Remote Configuration Changes Changing configuration values using the PLC editor is supported but requires that the settings be transferred...

Страница 20: ...on Manual Touchscreen invoked Functions Detailed information on these functions can be found in the TCU800 Installation and Operation Manual View process ID and version level Swipe to the Settings pag...

Страница 21: ...on See the Return Authorization RA Procedure next section for instructions on obtaining replacement parts Return Authorization RA Procedure In the event that a unit fails during or after the warranty...

Страница 22: ...uired during the repair of the module s the DFS service department will contact you To get information on the progress of any of your equipment in for repair contact the DFS RA Department at rma dataf...

Страница 23: ...22 Notes...

Страница 24: ...23 Notes...

Страница 25: ...Data Flow Systems Inc 605 N John Rodes Blvd Melbourne FL 32934 321 259 5009 www dataflowsys com...

Отзывы: