P
AGE
52
46512-0999 <90-00083>
E
DIT
1.
Press the N (Next) or P (Previous) key until you find the bay that
you want to edit.
2.
Highlight Edit.
3.
Press Enter. The Edit Bay menu appears.
Instructions for editing the bay memory and alarm levels, SLC
memory and alarm levels, and ACO duration appear below.
E
DIT
B
AY
M
EMORY
AND
A
LARM
L
EVELS
To edit a bay memory and alarm level:
1.
Highlight Edit Bay Memory and Alarm Levels.
2.
Press Enter.
3.
In the MAP Dsp field, type the location in the MAP’s memory
where the SLC 96 bay resides. Acceptable memory locations are
1-64 or 1-128, depending on how many alarm displays the MAP
reports.
4.
Press Enter.
EDIT MEMORY AND ALARM LEVELS
To edit the SLC memory and alarm levels:
1.
Highlight Edit Memory and Alarm Levels.
2.
Press Enter.
3.
Change the MAP display numbers for selected SLC 96 devices.
4.
Press F10.
CHANGE ACO DURATION (GLOBAL)
To edit the ACO duration for all SLC 96 CPMs:
1.
Highlight Change ACO Duration (Global).
2.
Press Enter.
3.
Change the ACO duration. Valid values are 1-255.
4.
Press Enter.
SLC 96 Device Operation
SLC 96 devices work with a common bus that carries common
alarms. Non-multiplex (SYS) alarms are generated normally.
You can define a timing window, which is a period of time when
all alarms report, in the Downloaded MAP Options menu.
MAP SYSTEM DEFINITION
CONTINUED
. . .