Technical specifications 

Performance data 

Variable speed drive  
specifications

Bearings lubrication

Compressor

model

Swept 

volume

Displacement

Oil charge

Net weight

cu.in/rev

Min speed

30 Hz

60 Hz

Max speed

oz

lb

900 rpm

1800 rpm

3600 rpm

4200 rpm

VRJ028

1.64

51

103

206

240

36

53

VRJ035

2.12

66

133

265

310

57

55

VRJ044

2.65

83

166

332

387

57

55

Compressor specifications

For dedicated variable speed drive specifications, 
refer to “Danfoss VRJ Installation and Operation 
instructions”.

A specific oil pump ensures optimal bearing 
lubrication at all compressor speeds. This to have 
sufficient bearing lubrication at low speeds as well 

as avoid excessive Oil Circulation Ratio (OCR) at 
high speeds.

Conditions

Compressor 
model

Nominal 
Tons

Compressor speed

Compressor capacity

Compressor 

isentropic efficiency

rpm

Hz

Btu/hr

Ton

High SEER 

conditions 

(H)

VRJ028

3 Tons

3600

60

36700

3.06

66.2

4200

70

42700

3.56

64.9

VRJ035

4 Tons 

3600

60

46400

3.87

67.6

4200

70

53400

4.45

65.1

VRJ044

5 Tons

3600

60

57800

4.82

68.3

4200

70

68100

5.68

67.0

CHEER 

conditions

VRJ028

3 Tons

3600

60

36500

3.04

65.9

4200

70

42300

3.53

64.3

VRJ035

4 Tons

3600

60

46200

3.85

67.3

4200

70

53000

4.42

64.6

VRJ044

5 Tons

3600

60

57900

4.83

68.8

4200

70

68300

5.69

67.5

Heat Pump 

conditions

VRJ028

3 Tons

3600

60

25100

2.09

59.7

4200

70

29300

2.44

58.8

VRJ035

4 Tons

3600

60

31800

2.65

61.0

4200

70

36700

3.06

59.0

VRJ044

5 Tons

3600

60

40200

3.35

62.2

4200

70

47300

3.94

61.2

SEER 

conditions (I)

VRJ028

3 Tons

1800

30

21000

1.75

68.5

VRJ035

4 Tons

1800

30

26800

2.23

69.7

VRJ044

5 Tons

1800

30

34500

2.88

70.9

Conditions 

Evaporating 

Temperature 

(°F)

Condensing 

Temperature 

(°F)

Superheat 

(°F)

Subcooling

(°F)

High SEER 

conditions (H) 

50

115

20

15

CHEER 

conditions

45

100

20

15

Heat Pump 

conditions

30

110

20

15

SEER 

conditions (I)

55

100

20

15

Содержание VRJ

Страница 1: ...Danfoss Inverter scroll compressor VRJ For Residential Applications R410A Application Guidelines http danfoss us com...

Страница 2: ......

Страница 3: ...pply 11 Compressor ambient temperature 11 Application envelope 12 High and low pressure protection 13 Crankcase heating 13 Oil return management 13 On off cycling cycle rate limit 14 Start up sequence...

Страница 4: ...lect a compressor size that achieves the peak load system cooling capacity demand at its maximum speed Nominal cooling capacity select a compressor size that achieves the nominal system cooling capaci...

Страница 5: ...git serial number 12345678 A 25 B Plant assembly line code Month code Application Family refrigerant V Variable speed R Residential J R410A PVE lubricant Swept Volume Displacement in cc rev Model Vari...

Страница 6: ...ompressor isentropic efficiency rpm Hz Btu hr Ton High SEER conditions H VRJ028 3 Tons 3600 60 36700 3 06 66 2 4200 70 42700 3 56 64 9 VRJ035 4 Tons 3600 60 46400 3 87 67 6 4200 70 53400 4 45 65 1 VRJ...

Страница 7: ...1 161 5 16 18 UNC self tapping Recommended torque for mounting bolts 8 ft lbs 1ft lbs 0 433 9 40 4 x 0 75 0 78 3 750 5 06 4 38 2 74 2 80 34 31 45 14 4 32 3 750 7 491 7 509 9 40 7 491 7 509 15 53 Suct...

Страница 8: ...ording to UL requirements With VRJ compressors the LRA value is low because the variable speed drive reacts very rapidly far below 1 second The MCC value is the maximum at which the compressor can be...

Страница 9: ...ion will be not possible If compressor and drive T1 T2 and T3 terminals are not matching the compressor can go in reverse rotation This results in excessive noise no pressure differential between suct...

Страница 10: ...ive 97 23 EC Low voltage directive 73 23 EC 93 68 EC Internal free volume Manufacturer s declaration of incorporation ref EC Machines Directives 98 392 CE Contact Danfoss Products Internal free volume...

Страница 11: ...bricant provides the best possible result in terms of reliability and compressor lifetime Although the compressor itself can withstand low ambient temperature the system may require specific design fe...

Страница 12: ...controller software s The discharge temperature depends mainly on the combination of evaporating temperature condensing temperature and suction gas superheat and speed Discharge gas temperature should...

Страница 13: ...y switch loss of charge safety switch setting is given in the above table Either the LP safety switch must be a manual lockout device or an automatic switch wired into an electrical lockout circuit Th...

Страница 14: ...arts VRJ compressors start with a defined ramp up and stay at a fixed speed for some seconds Then the compressor speed increases up to the desired set point according to capacity request On off cyclin...

Страница 15: ...ide of the compressor during off cycle The upper loop also helps avoid condensed liquid refrigerant from draining back to the compressor when stopped see fig 2 The maximum elevation difference between...

Страница 16: ...ronic expansion valve for all air conditioning and heat pump applications with VRJ compressors An EXV has two key benefits it provides modulating control of the system under varying load conditions an...

Страница 17: ...onnected to the drive Water utilising systems Apart from residual moisture in the system after commissioning water could also enter the refrigeration circuit during operation Water in the system shall...

Страница 18: ...long the parts of the unit and structure Gas pulsation This tends to travel through the cooling medium i e the refrigerant The following sections will focus on the causes and methods of mitigation for...

Страница 19: ...constitutes the primary method for controlling structural vibration VRJ scroll compressors are designed to produce minimal vibration during operations The use of rubber isolators on the compressor ba...

Страница 20: ...ust be taken never drill holes into the pipe work after installation Compressors are provided with a lifting lug This lug should always be used to lift the compressor Once the compressor is installed...

Страница 21: ...lux is acidic and can cause substantial damage to the internal parts of the system and compressor The PVE oil used in VRJ compressors is highly hygroscopic and will rapidly absorb moisture from the ai...

Страница 22: ...sulation resistance must be greater than 1 megohm when measured with a 500 volt direct current megohm tester Each compressor motor is tested at the factory with a high potential voltage hi pot that ex...

Страница 23: ...ping US thread bolts washers and sleeves Industrial pack Ordering code numbers Compressors are not packed individually but are shipped all together on one pallet They can be ordered in quantities of f...

Страница 24: ...nd positioned us as distinct variable speed technology specialists Today we operate from engineering and manufacturing facilities spread across three continents Danfoss Inverter Scrolls Danfoss Turboc...

Отзывы: