9-65 Profile Number
Range:
Function:
0
*
[0 - 0 ] This parameter contains the profile identification.
Byte 1 contains the profile number and byte 2 the
version number of the profile.
NOTICE
This parameter is not visible via LCP.
9-70 Programming Set-up
Option:
Function:
Select the set-up to be edited.
[0] Factory setup Uses default data. This option can be used as
a data source to return the other set-ups to a
known state.
[1] Set-up 1
Edits Set-up 1.
[2] Set-up 2
Edits Set-up 2.
[3] Set-up 3
Edits Set-up 3.
[4] Set-up 4
Edits Set-up 4.
[9] Active Set-up Follows the active set-up selected in
0-10 Active Set-up
.
This parameter is unique for LCP and fieldbuses. See
0-11 Programming Set-up
.
9-71 Profibus Save Data Values
Option:
Function:
Parameter values changed via PROFINET are not
automatically stored in non-volatile memory. Use
this parameter to activate a function that stores
parameter values in the EEPROM non-volatile
memory, so changed parameter values will be
retained at power-down.
[0] Off
Deactivates the non-volatile storage function.
[1] Store all
setups
Stores all parameter values for all set-ups in the
non-volatile memory. The selection returns to
[0]
Off
when all parameter values have been stored.
[2] Store all
setups
Stores all parameter values for all set-ups in the
non-volatile memory. The selection returns to
[0]
Off
when all parameter values have been stored.
9-72 ProfibusDriveReset
Option:
Function:
[0] No action
[1] Power-on
reset
Resets frequency converter upon power-up, as
for power-cycle.
[3] Comm
option reset
Resets the PROFINET option only, the
PROFINET option goes through a power-up
sequence.
When reset, the frequency converter
disappears from the fieldbus, which may
cause a communication error from the master.
9-80 Defined Parameters (1)
Array [116]
No LCP access
Read only
Range:
Function:
0
*
[0 - 9999 ] This parameter displays a list of all the defined
frequency converter parameters available for
PROFINET.
9-81 Defined Parameters (2)
Array [116]
No LCP access
Read only
Range:
Function:
0
*
[0 - 9999 ] This parameter displays a list of all the defined
frequency converter parameters available for
PROFINET.
9-82 Defined Parameters (3)
Array [116]
No LCP access
Read only
Range:
Function:
0
*
[0 - 9999 ] This parameter displays a list of all the defined
frequency converter parameters available for
PROFINET.
9-83 Defined Parameters (4)
Array [116]
No LCP access
Read only
Range:
Function:
0
*
[0 - 9999 ] This parameter displays a list of all the defined
frequency converter parameters available for
PROFINET.
9-84 Defined Parameters (5)
Array [115]
No LCP access
Read only
Range:
Function:
0
*
[0 - 9999 ] This parameter displays a list of all the defined
frequency converter parameters available for
PROFINET.
9-90 Changed Parameters (1)
Array [116]
No LCP access
Read only
Range:
Function:
0
*
[0 - 9999 ] This parameter displays a list of all the
frequency converter parameters deviating from
default setting.
Parameters