8.3 Parameter Group 9-** PROFIdrive
9-15 PCD Write Configuration
Array [10]
Option: Function:
Select the parameters to be assigned to PCD 3 to 10 of
the telegrams. The number of available PCDs depends
on the telegram type. The values in PCD 3 to 10 will
then be written to the selected parameters as data
values. Alternatively, specify a standard Profibus
telegram in
9-22 Telegram Selection
.
9-16 PCD Read Configuration
Array [10]
Option: Function:
Select the parameters to be assigned to PCD 3 to 10 of
the telegrams. The number of available PCDs depends
on the telegram type. PCDs 3 to 10 contain the actual
data values of the selected parameters. For standard
Profibus telegram, see
9-22 Telegram Selection
.
9-22 Telegram Selection
Option:
Function:
Select a standard Profibus telegram
configuration for the frequency
converter, as an alternative to using
the freely configurable telegrams in
9-15 PCD Write Configuration
and
9-16 PCD Read Configuration
.
[1]
Standard telegram 1
[101] PPO 1
[102] PPO 2
[103] PPO 3
[104] PPO 4
[105] PPO 5
[106] PPO 6
[107] PPO 7
[108] PPO 8
9-23 Parameters for Signals
Array [1000]
Read only
Option:
Function:
This parameter
contains a list of
signals available for
selection in
9-15 PCD
Write Configuration
and
9-16 PCD Read
Configuration
.
[0]
None
[302]
Minimum Reference
[303]
Maximum Reference
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
9-23 Parameters for Signals
Array [1000]
Read only
Option:
Function:
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[382]
Starting Ramp Up Time
[411]
Motor Speed Low Limit [RPM]
[413]
Motor Speed High Limit [RPM]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator Mode
[590]
Digital & Relay Bus Control
[593]
Pulse Out #27 Bus Control
[595]
Pulse Out #29 Bus Control
[597]
Pulse Out #X30/6 Bus Control
[653]
Terminal 42 Output Bus Control
[663]
Terminal X30/8 Output Bus Control
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[894]
Bus Feedback 1
[895]
Bus Feedback 2
[896]
Bus Feedback 3
[1500] Operating hours
[1501] Running Hours
[1502] Input kWh Counter
[1600] Control Word
[1601] Reference [Unit]
[1602] Reference [%]
[1603] Status Word
[1605] Main Actual Value [%]
[1609] Custom Readout
[1610] Input Power [kW]
[1611] Input Power [hp]
[1612] Motor Voltage
[1613] Frequency
[1614] Motor current
[1615] Frequency [%]
[1616] Torque [Nm]
[1617] Speed [RPM]
[1618] Motor Thermal
[1622] Torque [%]
[1630] DC Link Voltage
[1632] Brake Energy /s
[1633] Brake Energy /2 min
[1634] Heatsink Temp.
[1635] Inverter Thermal
[1638] SL Controller State
[1639] Control Card Temp.
[1650] External Reference
[1652] Feedback[Unit]
[1653] Digi Pot Reference
[1654] Feedback 1 [Unit]
Parameters
Operating Instructions
MG90U302
Danfoss A/S © Rev. 2014-02-27 All rights reserved.
47
8
8