Type Designation
P5K5
P7K5
P11K
High/Normal Overload
1)
HO
NO
HO
NO
HO
NO
Typical Shaft Output [kW]
5.5
7.5
7.5
11
11
15
Enclosure IP20
B3
B3
B4
Enclosure IP21, IP55, IP66
B1
B1
B2
Output current
Continuous (200-240 V) [A]
24.2
30.8
30.8
46.2
46.2
59.4
Intermittent (60 s overload) (200-240 V) [A]
38.7
33.9
49.3
50.8
73.9
65.3
Continuous kVA (208 V) [kVA]
8.7
11.1
11.1
16.6
16.6
21.4
Max. input current
Continuous (200-240 V) [A]
22.0
28.0
28.0
42.0
42.0
54.0
Intermittent (60 s overload) (200-240 V) [A]
35.2
30.8
44.8
46.2
67.2
59.4
Additional Specifications
IP20 max. cable cross-section
4)
for mains, brake, motor and load
sharing [mm
2
] ([AWG])
10,10,- (8,8,-)
10,10,- (8,8,-)
35,-,- (2,-,-)
IP21 max. cable cross-section
4)
for mains, brake and load sharing
[mm
2
] ([AWG])
16,10,16 (6,8,6)
16,10,16 (6,8,6)
35,-,- (2,-,-)
IP21 max. cable cross-section
4)
for motor [mm
2
] ([AWG])
10,10,- (8,8,-)
10,10,- (8,8,-)
35,25,25 (2,4,4)
Max. cable cross-section
4)
for Disconnect [mm
2
] ([AWG])
16,10,10 (6,8,8)
Estimated power loss at rated max. load [W]
3)
239
310
371
514
463
602
Efficiency
2)
0.96
0.96
0.96
Table 6.2 Mains Supply 200-240 V, P5K5-P11K
Type Designation
P15K
P18K
P22K
P30K
P37K
High/Normal Overload
1)
HO
NO
HO
NO
HO
NO
HO
NO
HO
NO
Typical Shaft Output [kW]
15
18.5
18.5
22
22
30
30
37
37
45
Enclosure IP20
B4
C3
C3
C4
C4
Enclosure IP21, IP55, IP66
C1
C1
C1
C2
C2
Output current
Continuous (200-240 V) [A]
59.4
74.8
74.8
88.0
88.0
115
115
143
143
170
Intermittent (60 s overload) (200-240 V) [A]
89.1
82.3
112
96.8
132
127
173
157
215
187
Continuous kVA (208 V [kVA]
21.4
26.9
26.9
31.7
31.7
41.4
41.4
51.5
51.5
61.2
Max. input current
Continuous (200-240 V) [A]
54.0
68.0
68.0
80.0
80.0
104
104
130
130
154
Intermittent (60 s overload) (200-240 V) [A]
81.0
74.8
102
88.0
120
114
156
143
195
169
Additional Specifications
IP20 max. cable cross-section for mains, brake,
motor and load sharing [mm
2
] ([AWG])
35 (2)
50 (1)
50 (1)
150 (300MCM) 150 (300MCM)
IP21, IP55, IP66 max. cable cross-section for
mains and motor [mm
2
] ([AWG])
50 (1)
50 (1)
50 (1)
150 (300MCM) 150 (300MCM)
IP21, IP55, IP66 max. cable cross-section for
brake and load sharing [mm
2
] ([AWG])
50 (1)
50 (1)
50 (1)
95 (3/0)
95 (3/0)
Max. cable cross-section
4)
for Disconnect [mm
2
]
([AWG])
50, 35, 35 (1, 2, 2)
95, 70, 70
(3/0, 2/0, 2/0)
185, 150, 120
(350MCM,
300MCM, 4/0)
Estimated power loss at rated max. load [W]
3)
624
737
740
845
874
1140
1143
1353
1400
1636
Efficiency
2)
0.96
0.97
0.97
0.97
0.97
Table 6.3 Mains Supply 200-240 V, P15K-P37K
Product Specifications
VLT
®
AutomationDrive FC 301/FC 302 Design Guide, 0.25-75 kW
MG33BF02 - Rev. 2013-12-20
59
6
6
Содержание VLT AutomationDrive FC 301
Страница 2: ......
Страница 199: ...Index VLT AutomationDrive FC 301 FC 302 Design Guide 0 25 75 kW MG33BF02 Rev 2013 12 20 197...