Lin
e P
o
wer
S
u
pp
ly 3 x
38
0–480
V AC
- Normal
ove
rl
o
ad 1
10% f
o
r 1
mi
nu
te
Ad
ju
st
ab
le fr
eq
ue
nc
y dr
ive
Typi
cal Sha
ft Outpu
t [kW]
PK
37
0.
37
PK
55
0.
55
PK7
5
0.
75
P1
K1
1.
1
P1
K5
1.
5
P2
K2
2.
2
P3
K0
3
P4
K0
4
P5
K5
5.5
P7
K5
7.
5
Typi
cal Sh
aft
Outp
ut
[HP
] at
460 V
0.
5
0.
75
1.
0
1.
5
2.
0
2.
9
4.
0
5.3
7.5
10
IP 20 / NE
M
A
Cha
ssis
A2
A2
A2
A2
A2
A2
A2
A2
A3
A3
IP
21 / NEM
A
1
IP
55 / NEM
A
12
A5
A5
A5
A5
A5
A5
A5
A5
A5
A5
IP 66
A5
A5
A5
A5
A5
A5
A5
A5
AA
A5
Out
p
u
t c
u
rr
en
t
Conti
nuo
us (3
x
38
0–44
0
V)
[A]
1.
3
1.
8
2.
4
3
4.
1
5.
6
7.2
10
13
16
Interm
ittent
(3
x
380
–440 V
) [A]
1.
43
1.
98
2.
64
3.
3
4.
5
6.
2
7.
9
11
14
.3
17.
6
Conti
nuo
us (3
x
44
1–48
0
V)
[A]
1.
2
1.
6
2.
1
2.
7
3.
4
4.
8
6.3
8.2
11
14.
5
Interm
ittent
(3
x
441
–480 V
) [A]
1.
32
1.
76
2.
31
3.
0
3.
7
5.
3
6.
9
9.0
12
.1
15.
4
Conti
nuo
us
kV
A
(400 V AC) [
kV
A]
0.
9
1.
3
1.
7
2.
1
2.
8
3.
9
5.0
6.9
9.0
11.
0
Conti
nuo
us
kV
A
(460 V AC) [
kV
A]
0.
9
1.
3
1.
7
2.
4
2.
7
3.
8
5.
0
6.5
8.8
11.
6
Ma
x.
cabl
e
size:
(li
ne
po
we
r, mo
tor,
brake
)
[[mm
2
/ AW
G]
2)
4/
10
Ma
x.
in
pu
t c
u
rr
en
t
Conti
nuo
us (3
x
38
0–44
0
V)
[A]
1.
2
1.
6
2.2
2.
7
3.
7
5.
0
6.
5
9.
0
11.
7
14
.4
Interm
ittent
(3
x
380
–440 V
) [A]
1.
32
1.76
2.4
2
3.0
4.
1
5.5
7.
2
9.
9
12.
9
15.8
Conti
nuo
us (3
x
44
1–48
0
V)
[A]
1.
0
1.
4
1.9
2.
7
3.
1
4.
3
5.
7
7.
4
9.9
13
.0
Interm
ittent
(3
x
441
–480 V
) [A]
1.
1
1.
54
2.0
9
3.
0
3.
4
4.
7
6.
3
8.
1
10.
9
14.3
Ma
x.
p
re-f
uses
1)
[A
]
10
10
10
10
10
20
20
20
30
30
En
vi
ro
nm
en
t
Estim
ated power l
oss
at
r
at
ed
m
ax
.
lo
ad
[W
]
4)
35
42
46
58
62
88
116
124
187
25
5
We
ig
ht e
nclo
sure
I
P2
0 [
kg
]
4.
7
4.7
4.8
4.8
4.
9
4.9
4.
9
4.
9
6.6
6.6
W
eight enclosure IP
21
[kg]
We
ig
ht e
nclo
sure
I
P
55
[kg
]
13.
5
13.5
13.
5
13.5
13.
5
13.5
13.
5
13.
5
14.
2
14.2
W
eight enclosure IP
66
[kg]
13.
5
13
.5
13.
5
13
.5
13.
5
13
.5
13.
5
13.
5
14.
2
14
.2
Eff
ici
ency
3)
0.
93
0.
95
0.9
6
0.
96
0.
97
0.
97
0.
97
0.
97
0.9
7
0.
97
3.1.4
Line Power
Supply 3
x
380
–48
0 V
AC
3 VLT AQUA Selection
VLT
®
AQUA Drive Design Guide
3-6
MG.20.N5.22 - VLT
®
is a registered Danfoss trademark
3
Содержание vlt aqua
Страница 4: ...Contents VLT AQUA Drive Design Guide MG 20 N5 22 VLT is a registered Danfoss trademark...
Страница 168: ...5 How to Install VLT AQUA Drive Design Guide 5 50 MG 20 N5 22 VLT is a registered Danfoss trademark 5...
Страница 186: ...6 Application Examples VLT AQUA Drive Design Guide 6 10 MG 20 N5 22 VLT is a registered Danfoss trademark 6...