![Danfoss vlt aqua Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/danfoss/vlt-aqua/vlt-aqua_design-manual_3693315065.webp)
1.
Rise time increases/decreases proportionally with cable length.
2.
U
PEAK
= DC-link voltage x 1.9
(DC-link voltage = AC line voltage x 1.35).
3.
dU
/
dt
=
0.8 ×
UPEAK
Risetime
Data are measured according to IEC 60034-17.
Cable lengths are in meters.
FC 202, P7K5T2
Cable length [m]
AC line voltage [V]
Rise time [
μ
sec]
Vpeak [kV]
dU/dt [kV/
μ
sec]
5
230
0.13
0.510
3.090
50
230
0.23
2.034
100
230
0.54
0.580
0.865
150
230
0.66
0.560
0.674
FC 202, P11KT2
Cable length [m]
AC line voltage [V]
Rise time [
μ
sec]
Vpeak [kV]
dU/dt [kV/
μ
sec]
36
240
0.264
0.624
1.890
136
240
0.536
0.596
0.889
150
240
0.568
0.568
0.800
FC 202, P15KT2
Cable length [m]
AC line voltage [V]
Rise time [
μ
sec]
Vpeak [kV]
dU/dt [kV/
μ
sec]
30
240
0.556
0.650
0.935
100
240
0.592
0.594
0.802
150
240
0.708
0.587
0.663
FC 202, P18KT2
Cable length [m]
AC line voltage [V]
Rise time [
μ
sec]
Vpeak [kV]
dU/dt [kV/
μ
sec]
36
240
0.244
0.608
1.993
136
240
0.568
0.580
0.816
150
240
0.720
0.574
0.637
FC 202, P22KT2
Cable length [m]
AC line voltage [V]
Rise time [
μ
sec]
Vpeak [kV]
dU/dt [kV/
μ
sec]
36
240
0.244
0.608
1.993
136
240
0.568
0.580
0.816
150
240
0.720
0.574
0.637
FC 202, P30KT2
Cable length [m]
AC line voltage [V]
Rise time [
μ
sec]
Vpeak [kV]
dU/dt [kV/
μ
sec]
15
240
0.194
0.626
2.581
50
240
0.252
0.574
1.822
150
240
0.488
0.538
0.882
VLT
®
AQUA Drive Design Guide
3 VLT AQUA Selection
MG.20.N5.22 - VLT
®
is a registered Danfoss trademark
3-21
3
Содержание vlt aqua
Страница 4: ...Contents VLT AQUA Drive Design Guide MG 20 N5 22 VLT is a registered Danfoss trademark...
Страница 168: ...5 How to Install VLT AQUA Drive Design Guide 5 50 MG 20 N5 22 VLT is a registered Danfoss trademark 5...
Страница 186: ...6 Application Examples VLT AQUA Drive Design Guide 6 10 MG 20 N5 22 VLT is a registered Danfoss trademark 6...