VLT® 5000 Crane
■
Service Functions
600-605 Operating Data
Value:
Par. no.
Description
Display text
Unit
Range
600
Operating hours
(OPERATING HOURS)
Hours
0-130,000.0
601
Hours run
(RUNNING HOURS)
Hours
0-130,000.0
602
kWh counter
(KWH COUNTER)
kWh
Depends on unit
603
Number of power-ups
(POWER UPS)
Number of times
0-9999
604
Number of
overtemperatures
(OVER TEMPS)
Number of times
0-9999
605
Number of overvoltages
(OVER VOLTS)
Number of times
0-9999
Function:
These parameters can be read out via the serial
communication port and the LCP control unit.
Description of choice:
Parameter 600, Operating hours:
Gives the number of hours the frequency converter has
been operating. The value is saved every hour and
when there is a mains failure. This value cannot be reset.
Parameter 601, Hours run:
Gives the number of hours the motor has been
operating since the reset in parameter 619
Reset
of hours-run counter
. The value is saved every
hour and when there is a mains failure.
Parameter 602, kWh counter:
Gives the frequency converter
’
s output energy in
kWh. The calculation is based on the mean kW
value over one hour. This value can be reset using
parameter 618
Reset of kWh counter
.
Range: 0 - depends on unit.
Parameter 603, Number of power-ups:
Gives the number of power-ups of the supply voltage
undertaken on the frequency converter.
Parameter 604, Number of overtemperatures:
Gives the number of overtemperature faults that have
been registered on the frequency converter
’
s heat sink.
Parameter 605, Number of overvoltages:
Gives the number of overvoltages of the intermediate
circuit voltage in the frequency converter. This is only
counted when Alarm 7
Overvoltage
is active.
615 F. LOG: ERROR CODE
Value:
Table with error codes, see
Warnings and Alarms
Function:
This parameter makes it possible to see the
reason why a trip occurs.
10 (0-9) log values are stored.
The lowest log number (0) contains the latest/most
recently saved data value; the highest log number
(9) contains the oldest data value.
Description of choice:
Given as a number code, in which the trip
number refers to an alarm code.
Reset the fault log after manual initialisation.
616 F.LOG: TIME
Function:
This parameter makes it possible to see the total
number of operating hours before the trip occurred.
10 (0-9) log values are stored.
The lowest log number (0) contains the latest/most
recently saved data value, while the highest log
number (9) contains the oldest data value.
Description of choice:
Indication range: 0.0 - 9999.9.
Reset the fault log after manual initialisation.
617 F.LOG:VALUE
Value:
[Index 0.0 - 999.9]
Function:
This parameter makes it possible to see at what
current or voltage a given trip occurred.
✭
= factory setting. () = display text [] = value for use in communication via serial communication port