
YR must be set at the negative equivalent and YL must be set at the positive equivalent
(See example). The default value for YR and YL is set equal to the mechanical locks of the steering
actuator resulting in the vehicle to steer in the right direction.
Yxsat Sets a threshold for the output to be at its maximum or minimum when the input signal exceeds
the threshold value. Yxsat is normally set down when more sensitivity is required than inherently
available with the steering device. The default value will not effect the inherent sensitivity of the steering
device.
Symbol
Index
Default
Value range
db
3y05
0
0.0 to 250 (0.0 to 25.0% of max activation in the right steering direction)
Lx
3y06
0
-10 to 10 (-10 max regress, 0 linear, 10 max progress)
YR
3y07
1000
-1000 to 1000
YL
3y08
-1000
-1000 to 1000
Yxsat
3y03
1000
251 to 1000
Parameter Yxsat, db & Lx have same value in quadrant 2 & 3. Lx in quadrant 1 or 4 is located at: [(Xysat+db)/2; YR*(20-Lx)/40]. Lx in quadrant 2 or 3 is
located at: [-(Xysat+db)/2; YL*(20-Lx)/40].
Closing the Loop
Kp Amplifies the error between set point and current position. The optimum value for Kp is found when a
non-lagging, accurate, non-oscillating steering actuation without overshoot is achieved at extreme low
and high oil viscosities as specified in chapter: (robustness to changes sin dead times) and at low and
near max steering pressure when driving at low, high vehicle speed and reversed gear (robustness to
changes in damping & dead times). Moreover, Kp is closely related to valve capacity, stroke volume. See
section
on page 56 for information on accuracy. The default value fits to steering
systems with a lock-to-lock time of 2 seconds at max port flow.
Qm Sets the maximum port flow. It effects the speed of the steering actuator to move towards the set
point position. Negative values of Qm are interpreted as the positive equivalent.
The default value is set equal to the inherent max port flow capacity of the valve and will therefore not
have any effect.
Symbol
Index
Default
Value range
Kp
308
50
0 to 200 (0.00 to 2.00% of port flow capacity of the valve for 0.1% positional
error)
Qm
3y27
1000
0 to 1000 (0.0 to 100.0 % port flow)
Eliminate Noise due to Frequent Pressure Build-up
Eliminating noise is accomplished by stopping the controller to respond to minor deviations between set
point and current actuator position. The spool inside the valve is set in neutral when the port flow
command has been within a threshold value (Qth) for a given time (Tclpout). The spool is reactivated
again when port flow command exceeds the threshold.
Tclpout Sets the time delay (ms) before the main spool is set in neutral.
Qth Sets the threshold value for port flow command when the controller is in steady state.
Symbol
Index
Default
Value range
Tclpout
317
3000
1 to 30000 (ms)
Qth
318
50
0 to 100 (0.0 to 10.0% of max port flow)
Magnetic Valves OFF Control
Magnetic valves off delay time Disables the magnetic valve bridge after a time specified in ms when the
flow request is 0, otherwise it remains enabled. This parameter is used when electrical energy
Operation Manual
PVED-CL Controller for Electro-Hydraulic Steering, Version 1.38
Steering by High Priority Steering Device – Closed Loop
74 |
©
Danfoss | May 2016
11025583 | AQ00000216en-US0302