Loop flushing spool
Removal
1. Remove plugs (K0030) using a 24 mm hex wrench.
2. Remove and discard O-rings (K0030A).
3. Use a magnet to remove springs (K0020) and spool (K0010).
Inspection
Clean and inspect spool (K0010). If spool is damaged or worn replace it. Replace springs if they are
cracked or bent.
Reassembly
Loop flushing reassembly
K0010
K0030
K0030A
K0020
K0030
K0030A
K0020
67 N•m
[49 lbf•ft]
67 N•m [49 lbf•ft]
24 mm
24 mm
1. Lubricate and install spool (K0010).
2. Lubricate and install springs (K0020).
3. Lubricate and install new O-rings (K0030A).
4. Install plugs (K0030) using a 24 mm hex wrench with torque to 67 N•m [49 lbf•ft].
Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Minor repair
©
Danfoss | August 2018
AX00000025en-US0504 | 63