Shaft rotation direction
Shaft rotation direction is determined with a view from the shaft end.
Rotation direction of the motor will be dependent on the control option used as illustrated below.
Controls L1, L2, D1, D2, LH, DH
Direction of rotation
CCW
CW
P006030
B
A
Flow into port A = Clockwise
Flow into port B = CounterClockwise
Controls M1, M2, K1, K2, KH, MH
Direction of rotation
CCW
CW
P006031
B
A
Flow into port A = CounterClockwise
Flow into port B = Clockwise
Controls E1, E2, F1, F2, P1, P2, T1, T2, TA, TH, HE, HF
Direction of rotation
CCW
CW
P006032
B
A
Flow into port A = CounterClockwise
Flow into port B = Clockwise
1)
1 means 12 V
DC
and 2 means 24 V
DC
Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Operation
©
Danfoss | August 2018
AX00000025en-US0504 | 19