Customer ports
Size
060
080
110
160
210
250
Axial and radial
1)
DN19 typ 1
DN25 typ 1
DN25 typ 1
DN32 typ 1
DN32 typ 1
DN32 typ 1
Case drain ports
2)
0.875 [
7
∕
8
]–14UN-2B
1.0625 [1
1
∕
16
]–12UN-2B
1.313 [1
5
∕
16
]–12UN-2B]
Axial gauge
ports
2)3)
0.875 [
7
∕
8
]–14UN-2B
1.0625 [1
1
∕
16
]–12UN-2B
Radial gauge
port
2)3)
0.5625 [
9
∕
16
]–18UNF-2B
1)
Split flange Boss per ISO6162, 40 MPa series
2)
SAE O-ring boss
3)
Countersink may be deeper that specified in the standard.
Operating Parameters
Output Speed
Output Speed
Displacement
Unit
Size
060
080
110
160
210
250
Rated
Maximum 32°
min
-1
(rpm)
3600
3200
2900
2600
2350
2200
Minimum 6°
5900
5300
4800
4250
3850
3650
Zero 0°
6600
5950
5350
4750
4300
4050
Maximum
Maximum 32°
4500
4100
3700
3300
3000
2800
Minimum 6°
7250
6600
5950
5250
4800
4500
Zero 0°
7950
7200
6500
5750
5250
4900
System and Case Pressure, Ambient Temperature
Parameter
All sizes
System pressure
Maximum working
450 bar [6527 psi]
Maximum
480 bar [6962 psi]
Minimum
1)
2)
Case pressure
Rated
3 bar [44 psi]
Maximum
5 bar [73 psi]
Minimum
0.3 bar [4 psi]
Ambient temperature
3)
Maximum
70 °C [158 °F]
Minimum
-40 °C [-40 °F]
1)
Minimum above case pressure (open and closed circuit)
2)
See the graphs
Required inlet pressure diagrams (for cylinder block filling)
on page 16.
3)
Air temperature close to the unit.
Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Technical specifications
14 |
©
Danfoss | August 2018
AX00000025en-US0504