Service – 43
VMBMH302
14.2
Preventative measures
Some of the following points can also be used when troubleshooting.
z
z
z z
Do
not
install heat pumps on walls adjoining bedrooms.
z
z
z z
Ensure that
all
pipes are elastically suspended, with mountings as illustrated or similar. This is so that the
rubber (or similar material) compresses 1–2 mm under vibration. It is not recommended to suspend the
pipes from too many points, as the force at each mounting is then not sufficient.
Figure 33: Example of rubber mounting.
z
z
z z
If the ceiling of the boiler room is unsuitable for suspending the aforementioned pipe mountings from, set
up (or construct) special stands on the floor from which the pipes can be suspended.
z
z
z z
Ensure that the refrigerant pipes and similar pipes do not lie against walls that they run along and that foam
insulation is wrapped around the entire pipe, not just on top of it.
z
z
z z
Pipes inside the heat pump must not be against each other (if they are, clamp and secure suitable rubber,
pulling the pipes apart by hand only helps temporarily).
z
z
z z
Place the heat pump on rubber feet or synthetic vibration dampers designed for its weight.
z
z
z z
Do not forget flexible hoses, preferably lengths that enable them to be routed in a loop. If necessary, use
rubber straps to secure flexible hoses in position, so that they do not lie against each other or create vibra-
tion bridges.
z
z
z z
Ensure that electrical wiring is not put under strain, if it is it creates vibration bridges.
z
z
z z
If possible, prevent placing the heat pump in a cold cellar with hard concrete walls and unsuitable acous-
tics (test by clapping your hands; if there is a clear echo, the acoustics are unsuitable). The cellar can be
furnished or noise insulated. Check that the air intake for the boiler room is soundproofed to some extent
(damper or similar).
Soundproofing measures to carry out afterwards:
z
z
z z
Go through the aforementioned points and improve when possible.
z
z
z z
Hood for compressor (most effective for high frequencies).
z
z
z z
Improve the acoustic environment by installing acoustic panels on walls and in the ceiling.
z
z
z z
In some instances, it is recommended to move the heat pump to another room.
z
z
z z
In rare instances, it may be worth replacing the compressor.
H
Ø
D
G
h
1
h
2
Содержание DHP-AX
Страница 1: ...VMBMH302 Danfoss DHP AX Installation and Service instructions ...
Страница 7: ...Service 7 VMBMH302 Installation instructions ...
Страница 20: ...20 Service VMBMH302 Service instructions ...
Страница 41: ...Service 41 VMBMH302 ...
Страница 68: ...68 Service VMBMH302 ...
Страница 69: ...Service 69 VMBMH302 ...
Страница 70: ...VMBMH302 ...