44 – Service
VMBMH302
15
Troubleshooting
15.1
Alarm
Shown in display in the event of an alarm. To reset alarms 1-5, set the operating mode to OFF or cut the power
supply.
Message
Meaning
HIGH PRESSURE ERROR
Tripped high pressure switch. Compressor stopped. No hot water production.
LOW PRESSURE ERROR
Tripped low pressure switch. Compressor stopped. No hot water production.
MOTOR P ERROR
Deployed motor protection (Over current relay compressor), or deployed motor protection
for outdoor unit fan. Compressor stopped. No hot water production.
OUTDOOR SENSOR
Fault in outside sensor. When the control system calculates the heat demand, zero degrees
is used.
SUPPLY LINE SENSOR
Supply line sensor error. Everything stops except the heating system’s circulation pump.
RETURN LINE SENSOR
Return sensor fault. Return temperature = Supply line – 5 is used. Calculated supply tempe-
rature limited to maximum 45°C.
HOT WATER SENSOR
Fault on sensor for start temperature. No hot water production.
ERR PHASE SEQ.
Alarm that indicates that there is an incorrect phase sequence to the compressor. Only dis-
play and only the first 10 minutes.
HIGH RETURN
Alarm that indicates that high return temperature prevents the compressor’s operation.
RAD FLOW LOW
The flow sensor produces an alarm when the water flow in the heating system becomes too
low.
Содержание DHP-AX
Страница 1: ...VMBMH302 Danfoss DHP AX Installation and Service instructions ...
Страница 7: ...Service 7 VMBMH302 Installation instructions ...
Страница 20: ...20 Service VMBMH302 Service instructions ...
Страница 41: ...Service 41 VMBMH302 ...
Страница 68: ...68 Service VMBMH302 ...
Страница 69: ...Service 69 VMBMH302 ...
Страница 70: ...VMBMH302 ...