Service – 39
VMBMH302
13.2.5 Sub menu SERVICE -> INSTALLATION
Used for settings that are set during installation.
Menu selection
Meaning
Factory setting
ENGLISH
Language setting for the control system.
The button sequence that is to be pressed to access this menu to
change language is shown here:
(5 seconds), , , , , , .
You are now in the language menu, select language using or .
ENGLISH
(ÈEŠTINA,
POLSKI,
EESTI,
SUOMI,
DANSK,
NORSK,
ITALIANO,
ESPAÑOL,
FRANÇAIS,
NEDERLANDS,
DEUTSCH,
ENGLISH,
SVENSKA)
SYSTEM
Note! The menu selection
in the SYSTEM menu
varies depending on the
selected values. Tip: start
in the top menu and
work downwards.
Sub menu SERVICE -> INSTALLATION -> SYSTEM:
Menu selection
Meaning
HEAT SOURCE
AIR:
Menu selection Meaning
DIRECT
EVAPORATION
The actual system with direct evaporation and
4-way valve.
HEATING SYSTEM
VL SYSTEM
POOL
(Expansion card)
ON /
Cannot be selected if SHUNT GROUP is selected.
SHUNT GROUP
ON /
When ON, HEAT CURVE 2 is activated in the INFORMATION menu.
Cannot be selected if POOL is selected.
ADDITION
0-10V: (Expansion card)
CURRENT LIMITER: ON / (Expansion card)
PHASE FAULT: / PHASE READING
SERVICE TIME
NOTE!
Only used for test operation. The heat pump counts 60
times as fast, which means that the waiting times are eliminated
during test operation.
0 = deactivates SERVICE TIME
1 = activates SERVICE TIME which speeds up the control system’s
integral calculation and start delay by 60 times.
-
FACTORY SET
CANCEL = starting point, no changes made.
RADIATOR = reset factory settings for radiator system
FLOOR = reset factory settings for under floor heating
-
RESET OPER. TIME
0 = no reset of operation times
1 = reset operation times to zero
-
SENSOR CALIBRATION
Following sensors are in the installation:
OUTDOOR
SUPPLY LINE
RETURN LINE
HOT WATER
REFR 1
REFR 2
REFR 3
EXTERNAL FACTOR (these parameters affect all sensors except
the outdoor sensor. The parameter compensates for the external
influence on the sensor that is mounted in the heat pump.
Содержание DHP-AX
Страница 1: ...VMBMH302 Danfoss DHP AX Installation and Service instructions ...
Страница 7: ...Service 7 VMBMH302 Installation instructions ...
Страница 20: ...20 Service VMBMH302 Service instructions ...
Страница 41: ...Service 41 VMBMH302 ...
Страница 68: ...68 Service VMBMH302 ...
Страница 69: ...Service 69 VMBMH302 ...
Страница 70: ...VMBMH302 ...