10 – Installation
VMBMH302
3.3
Supplied contents
3.3.1
Control
1.
Check that there is no transport damage.
2.
Remove the packaging and check that the delivery,
except for the heat pump, contains the following
components.
3.3.2
Heat pump
Quantity Name
1
Heat pump
1
Flow sensor
Size
Name
Color Code
l/m
6kW
UR1-025TC-15
Black
7
8kW
UR1-025TC-14
Yellow
10
10kW
UR1-025TC-13
Red
12
12kW
UR1-025TC-16
Blue
14
3.3.3
Packaging
Quantity Name
1
Dirt filter with shut-off DN25
1
Outdoor sensor
1
Safety valve 1,5 bar 1/2”
1
Front cover
1
Control centre
1
4 m Supply line sensor
3.3.4
Document set
Quantity Name
1
Installation and service instructions
1
User manual
1
Electrical instructions
1
Decal sheet
1
Registration card (only for certain markets)
3.4
Transporting the heat pump
BB
D B
The heat pump must always be transported
and stored standing and in a dry environment.
If the heat pump is laid on the incorrect side it
may become seriously damaged as the oil in the
compressor can run out in the pressure pipe and
therefore prevent normal function.
BB
D B
Always secure the heat pump so that it cannot
tip over during transportation.
3.5
Space requirement
BB
D B
To ensure the function of the heat pump, there
must be at least 300 mm of space behind and
1500 mm at the front.
BB
E B
For maintenance work there must be approxi-
mately 300 mm of space at the sides.
Figure 3: Necessary service space for DHP-AX.
300 mm
300 mm
300 mm
1500 mm
400 mm
Содержание DHP-AX
Страница 1: ...VMBMH302 Danfoss DHP AX Installation and Service instructions ...
Страница 7: ...Service 7 VMBMH302 Installation instructions ...
Страница 20: ...20 Service VMBMH302 Service instructions ...
Страница 41: ...Service 41 VMBMH302 ...
Страница 68: ...68 Service VMBMH302 ...
Страница 69: ...Service 69 VMBMH302 ...
Страница 70: ...VMBMH302 ...