Service – 35
VMBMH302
13.1.5 Sub menu INFORMATION -> OPERAT. TIME
Used to show the operating time for each component. Time given in hours.
Menu selection
Meaning
Factory setting
HEAT PUMP
Compressor operating time for both heating and hot water pro-
duction.
-
AUX. HEAT 1
Operating time auxiliary heat step 1.
-
HOT WATER
Operating time hot water with compressor.
-
13.1.6 Sub menu INFORMATION -> DEFROST
This menu is used to obtain information about outdoor unit defrosting and to make certain settings.
Menu selection
Meaning
Factory setting
DEFROSTS
Total number of defrosts carried out.
-
BETW. 2 DEFR
The operating time of the compressor in minutes between the 2
last defrosts.
-
TIME LAST DEFR
The operating time of the compressor in minutes since last
defrost.
-
DEFROST CURVE
Here, the angle of the defrost curve can be changed using +
or – (Change the start temperature for defrost).
-7°C
(interval: -10°C / -4°C)
MANUAL DEFR
Use + or - to start a manual defrost.
0 (interval: 0 / 1)