43
The parameters in the following section are READ
ONLY and cannot be changed by the user . They pro-
vide information for technicians and OEM users .
NOTE:
the only parameters that can be configured are:
oEL, oEn, oEH.
These parameters allow OEMs to enter their own
product code.
7.12 Service Information /
Ser
Danfoss ERC 102
Hold 3 sec: Menu
1 Click: Variable direct function, e.g.ECO/Night mode
1 Click: Variable direct function, e.g. light
Sub function: Up
1 Click: Temperature setpoint
Sub function: Down
Sub function: Back
Sub function: OK
ERC Front and Button Functionallity:
1 Click: Temperature setpoint
ERC
102 Reference manual – 7 PARAMETERS
ERC menu
code
Default
Min
Max
Unit
Conv
Unit
Scale
Default Access
Shop Ser OEM
Service
SEr
DI
Sdi
---
oFF
on
no
-- R- R-
Voltage value
uAC
---
0
270
no
Vac
1
-- R- R-
DOs Status
ouS
---
IIII
IIII
no
-- R- R-
Relay 1 counter
rL1
---
0
999
no
1000
1000
-- R- R-
Relay 2 counter
rL2
---
0
999
no
1000
1000
-- R- R-
Relay 3 counter
rL3
---
0
999
no
1000
1000
-- R- R-
Relay 4 counter
rL4
---
0
999
no
1000
1000
-- R- R-
interval Counter
int
---
0
999
no
min
1
-- R- R-
Defrost time counter
dnt
---
0
999
no
min
1
-- R- R-
Door open counter
ont
---
0
999
no
1
1
-- R- R-
SW version
Fir
SWVER
-32768
32767
no
R- R- R-
HW version
HAr
HWVER
-32768
32767
no
R- R- R-
OrderNoLow
OnL
ORNOL
-32768
32767
no
-- -- --
OrderNoHigh
OnH
ORNOH
-32768
32767
no
-- -- --
OEM code Low
oEL
0
0
999
no
R- R- R-
OEM code Middle
oEn
0
0
999
no
R- R- R-
OEM code High
oEH
0
0
999
no
R- R- R-
Parameter version
PAr
PARVER
-32768
32767
no
R- R- R-
Last change
CHA
0
0
999
no
1
-- -- --
Manufacturing date
CHd
0
0
999
no
1
-- R- R-
Copy Key ID
Cid
0
0
999
no
1
-- -- R-
Set as Default
SFC
no
no
yES
no
RW RW RW