47
ERC menu
code
Description
Pull Down
Pud
Pull down settings
Pull-down Initiate
Temperature
Pit
If the cabinet temperature is above this temperature for >1h, pull-down mode is activated
Pull-down Cycling
PCy
Minimum duration [min] of the pull-down mode, starting at PiT
Pull-down defrost Interval
Pdi
Defrost interval during pull-down . Over-rules the defrost interval in normal mode .
Pull-down duration
Pdd
Maximum duration [min] of the pull-down mode, starting at PiT
Pull-down limit temp
PLt
A safety feature; the lowest temperature allowed during pull-down .
Pull-down reduction
temp Δt
Prt
A calculation value for pull-down performance improvement . Instructions: See manual
ERC menu
code
Description
Auto-Heater Control
AHC
Auto-Heater settings (only if heater fitted for outdoor use in cold climates)
Automatic heater mode
enable
AuH
yES: Activate heater if ambient temperature is below desired cabinet temperature
Energy mode delay
End
Delay in minutes between heater and compressor operation
Heater displacement
temperature
Hdi
Heater displacement or OFFSET temperature relative to desired temperature .
ERC menu
code
Description
Condenser Protection
Con
Condenser protection settings
Condenser Alarm Limit
CAL
If condenser sensor exceeds this temperature, alarm is activated
Condenser Block Limit
CbL
If this temperature is exceeded, compressor will be stopped .
Condenser OK limit
CoL
Temperature at which compressor may start after a stop due to exceeding CbL
Condenser Low Temp .
Limit
CLL
Temperature below which the compressor is not allowed to start
ERC menu
code
Description
Display
diS
Display settings
Display Unit
CFu
F: Fahrenheit; C: Celsius
Display Resolution
rES
Display resolution for temp: 0 .1, 0 .5 or 1 .0 C/F
Display Range Limit
rlt
Limits displayed temperature to actual se/- differential; may be illegal in some countries
Display Delay
ddL
Time period for moving average temperature display
Display Offset
doF
Display a different temperature relative to measured temperature
Lock-time After defrost
dLt
Display lock time after defrost [0-60 min]
Show Economy state
SEC
yES: display will show “Eco” when in Eco mode . nO: temperature will be shown
Show Pull Down state
SSC
yES: “SC “ will be displayed during Pull down; nO: “SC “ will not be displayed .
Show Defrost
SdF
yES: display will show deF during defrost ; no: Display will show temp
Display Intensity
din
Display intensity when no ambient sensor; min intensity with sensor
ERC
102 Reference manual – APPENDIX I: PARAMETER QUICK LIST